Studies on Giant Magnetostrictive Actuator for Disc Brake Application
Date
2016
Authors
Joshi, Raghavendra
Journal Title
Journal ISSN
Volume Title
Publisher
National Institute of Technology Karnataka, Surathkal
Abstract
The present study discusses the implementation of magnetostrictive actuation in disc
brake system for braking action. In line with this, disc for a caliper unit is chosen and
for a range of speeds, the axial braking force and braking torque required on each
frictional pad is estimated. Based on the axial force required, an appropriate size of
Terfenol-D rod is selected for the magnetostrictive actuator. A separate coil is used
for biasing instead of permanent magnet in addition to excitation coil in the layout of
a Terfenol-D actuator. The coaxial coils of Terfenol-D actuator are designed based on
the required magnetic field strength. The number of coil turns obtained for coaxial
coils with Ampere’s law is verified from reluctance approach. The shape factor of
coaxial coils were found to be, 0.1653 and 0.1154 for coil 1 and coil 2, respectively
which are close to 0.179 for maximum magnetic field at the centre of coils. The
magnetic flux densities of coaxial solenoids in free air are verified analytically,
experimentally and numerically using MAXWELL 2D solver. The distribution of
axial, radial magnetic flux density and flux distribution in the actuator assembly with
different housing materials namely mild steel, cast iron and aluminium with and
without Terfenol-D are discussed considering the effect of magnetic permeability of
housing materials. It is observed that the magnetic flux distribution is stronger in an
actuator with mild steel housing compared to cast iron and aluminium housing.
Theoretically, the magnetic field strength on a Terfenol-D rod is arrived at by taking
the inductance of driving coils. Energy based Jiles-Atherton model is used to
calculate the magnetization of a Terfenol-D material. Non-constitutive model takes
into account of parameters such as magnetization, applied prestress and Young’s
modulus to quantify the magnetostriction of a Terfenol-D material. The existing nonconstitutive magnetostriction model does not consider strain at resonance condition.
The strain or magnetostriction at resonance condition is accounted by the term called
quality factor. The present study considers the influence of quality factor into the
existing non-constitutive models. Two magnetostrictive models are proposed to
consider the influence of quality factor. The first magnetostriction model proposed
considers the quality factor on the magnetostriction due to applied prestress. Theiv
second magnetostriction model considers the quality factor on the magnetostriction
due to magnetization of Terfenol-D. Magnetostriction of a Terfenol-D material was
estimated using the proposed magnetostriction model I and II. The output obtained
from the proposed magnetostriction models are verified with experimental data as
well as quadratic and non-linear magnetostriction models from the literature.
Experiments were conducted on a Terfenol-D actuator for DC input under prestress
conditions. Performance parameters such as displacement, repeatability, step
response, and response time are measured. The results indicate a better performance
of the actuator at each point of excitation when step input is biased to one of the coils
instead of varying the step input equally to coaxial coils. Force exerted by a
Terfenol-D actuator is compared for zero and other prestress conditions using
magneto-mechanical coupling equations. Hydraulic amplification unit is designed
assuming amplification ratio of 5 to boost the displacement obtained from the
Terfenol-D actuator. Displacement and output energy capability of a Terfenol-D
actuator as well as displacement amplified Terfenol-D actuator are evaluated using
stiffness match principle. Based on stiffness ratio, theoretically the amplification ratio
is evaluated and verified with the value assumed in the design of amplification unit.
After amplification, the braking force and braking torque available at each annular
pad are evaluated from the theoretical and experiment output of a Terfenol-D actuator
under different preload conditions. Further, these results are verified with the results
obtained based on disc specifications. It is summarized that the braking force and
torque achieved at the annular pads of a caliper unit for an applied step input and
preload are sufficient to decelerate or stop the disc till the rated speed of 800 rpm.
Finally, attempts are made to verify the output at the end of a hydraulic amplification
unit without brake fluid by coupling a Terfenol-D actuator assembly.
Description
Keywords
Department of Mechanical Engineering, Terfenol-D, Disc brake, Coaxial coils, Maxwell 2D solver, Step input, Repeatability, Step response, Inductance of driving coils, Jiles-Atherton model, Quality factor, Hydraulic amplification unit, Stiffness match principle