Faculty Publications

Permanent URI for this communityhttps://idr.nitk.ac.in/handle/123456789/18736

Publications by NITK Faculty

Browse

Search Results

Now showing 1 - 2 of 2
  • Item
    Performance evaluation of partially filled high porosity metal foam configurations in a pipe
    (Elsevier Ltd, 2021) Jadhav, P.H.; Gnanasekaran, N.; Arumuga Perumal, D.A.; Mobedi, M.
    In this contemporary research, a parametric analysis of partially filled high porosity metallic foams in a horizontal conduit is performed to augment heat transfer with reasonable pressure drop. The investigation includes six different models filled partly with aluminium foam by varying internal diameter of foams from the wall side and external diameter of foam from the core of the tube. The pore density of the foam ranges from 10 to 45 PPI and their porosity varies from 0.90 to 0.95. Flow dynamics are captured using Darcy Extended Forchheimer model for the porous filled region and two-equation turbulence k-? model employed in clear region of the fluid. The local thermal non-equilibrium assumption is incorporated in porous filled region of the conduit to compute the heat transport characteristics. The results showed that the thermal performance factor of 10 PPI aluminium foam performs close to the 10 PPI expensive copper foam. The performance factor is found to be higher for 30 PPI aluminium foam amongst the PPI's of the foam considered. However, the performance factor is found to be 2.93, 2.22 and 1.73 for 30PPI, 45 PPI and 20PPI with their porosities of 0.92, 0.90 and 0.90, respectively for the model 1, model 2 and model 3 at lower Reynolds number of 4500 and then it decreases progressively with increasing flow rates of the fluid. The results of average wall temperature, average Nusselt number and Colburn j factor are also evaluated to obtain best possible performance. © 2021
  • Item
    Performance score based multi-objective optimization for thermal design of partially filled high porosity metal foam pipes under forced convection
    (Elsevier Ltd, 2022) Jadhav, P.H.; Trilok, G.; Gnanasekaran, N.; Mobedi, M.
    Optimization study in flow through metal foams for heat exchanging applications is very much essential as it involves variety of fluid flow and structural properties. Moreover, the identification of best combinations of structural parameters of metal foams for simultaneous improvement of heat transfer and pressure drop is a pressing situation. In this work, six different metal foam configurations are considered for the enhancement of heat transfer in a circular conduit. The foam is aluminum with PPI varying from 10 to 45 and almost the same porosity (0.90-0.95). The aluminum foams are chosen from the available literature and they are partially filled in the conduit to reduce the pressure drop. For a constant heat flux condition, the goal is to find out the efficient metal foam and configurations when air is considered as a working fluid. A special attention is paid to the preference between pressure drop and heat transfer enhancements. That is why TOPSIS optimization techniques with five different criteria (contains the combination of the weightage/priority of heat transfer and pressure drop) is used. Based on the numerical results of heat and fluid flow in conduit, it is found that when an equal importance is given to both heat transfer and friction effect, 30 PPI aluminum foam with 80% filling on the inner lateral of the pipe provides the best score as 0.8197. The best configuration and PPI for different preferences between friction and heat transfer enhancements is discussed in details. The Reynolds number varies from 4500 to 16500. © 2021 Elsevier Ltd