Journal Articles

Permanent URI for this collectionhttps://idr.nitk.ac.in/handle/123456789/19884

Browse

Search Results

Now showing 1 - 10 of 18
  • Item
    Joining of Inconel-625 alloy through microwave hybrid heating and its characterization
    (Elsevier Ltd, 2015) Badiger, R.I.; Narendranath, S.; Srinath, M.S.
    Joining of bulk metals using microwave energy is being explored as a new processing method in the era of high technology applications. The present work investigates the results of on-going project in which joining of Inconel-625 alloy has been effectively carried out through microwave hybrid heating. Characterization of the microwave developed joints is done through SEM, XRD, UTM and Vicker's microhardness tester. The microstructural analysis through scanning electron microscope exhibits a fully fused weld interface free from interfacial cracks. XRD study reveals the formation of carbides of Ni, Cr and Mo in the joint interface. The average Vicker's microhardness in the joint region observed was 360 ± 20 Hv. Assessment of tensile strength shows an ultimate tensile strength of 328 MPa with 9.04% elongation. Further the fractured joints are subjected to fractography study which possibly reveals a mixed mode fracture. © 2015 The Society of Manufacturing Engineers. Published by Elsevier Ltd. All rights reserved.
  • Item
    Eliminated Phototoxicity of TiO2Particles by an Atomic-Layer-Deposited Al2O3Coating Layer for UV-Protection Applications
    (Wiley-VCH Verlag, 2016) Jang, E.; Sridharan, K.; Park, Y.M.; Park, T.J.
    We demonstrate the conformal coating of an ultrathin Al2O3layer on TiO2nanoparticles through atomic layer deposition by using a specifically designed rotary reactor to eliminate the phototoxicity of the particles for cosmetic use. The ALD reactor is modified to improve the coating efficiency as well as the agitation of the particles for conformal coating. Elemental and microstructural analyses show that ultrathin Al2O3layers are conformally deposited on the TiO2nanoparticles with a controlled thickness. Rhodamine B dye molecules on Al2O3-coated TiO2exhibited a long life time under UV irradiation, that is, more than 2 h, compared to that on bare TiO2, that is, 8 min, indicating mitigation of photocatalytic activity by the coated layer. The effect of carbon impurities in the film resulting from various deposition temperatures and thicknesses of the Al2O3layer on the photocatalytic activity are also thoroughly investigated with controlled experimental condition by using dye molecules on the surface. Our results reveal that an increased carbon impurity resulting from a low processing temperature provides a charge conduction path and generates reactive oxygen species causing the degradation of dye molecule. A thin coated layer, that is, less than 3 nm, also induced the tunneling of electrons and holes to the surface, hence oxidizing dye molecules. Furthermore, the introduction of an Al2O3layer on TiO2improves the light trapping thus, enhances the UV absorption. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim
  • Item
    Investigation of Microstructure and Mechanical Properties of ECAP-Processed AM Series Magnesium Alloy
    (Springer New York LLC barbara.b.bertram@gsk.com, 2016) Gopi, K.R.; Shivananda Nayaka, H.S.; Sahu, S.
    Magnesium alloy Mg-Al-Mn (AM70) was processed by equal channel angular pressing (ECAP) at 275 °C for up to 4 passes in order to produce ultrafine-grained microstructure and improve its mechanical properties. ECAP-processed samples were characterized for microstructural analysis using optical microscopy, scanning electron microscopy, and transmission electron microscopy. Microstructural analysis showed that, with an increase in the number of ECAP passes, grains refined and grain size reduced from an average of 45 to 1 µm. Electron backscatter diffraction analysis showed the transition from low angle grain boundaries to high angle grain boundaries in ECAP 4 pass sample as compared to as-cast sample. The strength and hardness values an showed increasing trend for the initial 2 passes of ECAP processing and then started decreasing with further increase in the number of ECAP passes, even though the grain size continued to decrease in all the successive ECAP passes. However, the strength and hardness values still remained quite high when compared to the initial condition. This behavior was found to be correlated with texture modification in the material as a result of ECAP processing. © 2016, ASM International.
  • Item
    Performance evaluation of reactive powder concrete with polypropylene fibers at elevated temperatures
    (Elsevier Ltd, 2018) Hiremath, P.N.; Yaragal, S.C.
    Reactive Powder Concrete (RPC) is a type of ultra-high strength concrete. Due to its dense microstructure, is vulnerable to explosive spalling at elevated temperatures. Remarkable application of RPC in special structures throughout the world has drawn the attention to understand the performance of RPC at elevated temperatures, which has not been investigated extensively yet. The main objective of this work was to evaluate the performance of RPC at elevated temperatures from 200 °C to 800 °C, by obtaining residual mechanical properties after exposure. The study aims to find an optimum fiber dosage for spalling protection of RPC. To improve the mechanical properties, RPC incorporating fiber dosage from 0.1% to 0.9% is studied. The thermal deterioration of RPC is assessed using ultrasonic pulse velocity, water absorption and sorptivity. Results shows that 0.1% fiber dosage is enough to control spalling of RPC up to 800 °C. To enhance the residual properties of RPC exposed to elevated temperatures, it is recommended to use fiber dosage of 0.5%. The study also includes microstructural analysis of RPC subjected to elevated temperatures, to assess and evaluate the formation of pores and cracks. © 2018 Elsevier Ltd
  • Item
    Effect of heat treatment on microstructure, corrosion, and shape memory characteristics of laser deposited NiTi alloy
    (Elsevier Ltd, 2018) Marattukalam, J.J.; Balla, V.K.; Das, M.; Bontha, S.; Kalpathy, S.K.
    The aim of this work is to study the effect of heat treatment on the microstructure, phase transformations, shape memory characteristics and corrosion behaviour of laser deposited equiatomic NiTi alloy. Dense samples of NiTi alloy were fabricated using Laser Engineered Net Shaping (LENS™) with two different laser energy densities by varying the scan speed and laser power. These samples were annealed for 30 min at 500 °C and 1000 °C in flowing argon, followed by furnace-cooling to room temperature. The resulting microstructures and properties were compared with the corresponding as-deposited samples. Microstructural analysis after heat treatment showed needle-shape martensite in the samples processed at lower laser energy density of 20 J/mm2, and lenticular or plate-like martensite in the samples processed at 80 J/mm2. The XRD results revealed relatively high concentration of martensite (B19?) in heat-treated NiTi alloy compared to as-processed samples. Furthermore, the heat treatment decreased the forward and reverse transformation temperatures of NiTi alloy from 80 – 95 °C to 20–40 °C, presumably due to annihilation of thermally induced defects. Interestingly, the samples annealed at 500 °C showed a measurable increase of 1–2% in the shape memory recovery, from the net recovery of 8% exhibited by the as-processed NiTi alloy. The corrosion resistance of laser-processed NiTi alloy decreased upon annealing. © 2018 Elsevier B.V.
  • Item
    Investigation of microstructure and mechanical properties of the Cu-3% Ti alloy processed by multiaxial cryo-forging
    (Cambridge University Press, 2018) Ramesh, S.; Shivananda Nayaka, H.; Gopi, K.R.; Sahu, S.; Kuruveri, U.B.
    A Cu-3%Ti (wt%) alloy was processed by multiaxial forging (MAF) at cryogenic temperature up to 3 cycles, imposing a total strain of 1.6. Microstructure and mechanical properties of the unprocessed and cryo-forged samples were analyzed. X-ray diffraction results showed deviation in peak broadening and peak intensity of the cryo-forged samples in comparison to that of unprocessed, which are due to texture modification caused by grain refinement during the MAF process. Microstructural analysis showed reduction in grain size from 80 m in the as-received condition to 250 nm after 3 cycles. Electron backscatter diffraction results indicated the transformation of high angle grain boundaries to low angle grain boundaries in all 3 cycles when compared to the as-received condition. Reduction in ductility was observed after 1 cycle, but with an increase in the number of cycles, both strength and ductility increased. After 3 cycles, ultimate tensile strength and hardness reached 1126 MPa and 427 Hv as compared to 528 MPa and 224 Hv for the as-received condition. Fractography analysis showed decrement in dimple size after 1 cycle, in comparison to that of the as-received condition. However, it kept on increasing for higher number of cycles. © © Materials Research Society 2018.
  • Item
    Microstructure, mechanical and wear properties of the A357 composites reinforced with dual sized SiC particles
    (Elsevier Ltd, 2019) Avinash, A.; Bontha, S.; Krishna, M.; Koppad, P.G.; Ramprabhu, T.
    Current work reports on the development of A357 alloy composite which is reinforced with dual size SiC particles by stir casting route. Influence of different weight fractions (3% coarse+ 3% fine, 4% coarse + 2% fine, and 2% coarse + 4% fine) of dual size SiC particles on mechanical properties and wear resistance of A357 composites is the focus of this work. Hardness and tensile properties were studied for dual size composites and then were compared with A357 alloy. Microstructural study, fractured surface and worn surface investigation were carried out using optical and scanning electron microscopes respectively. Microstructural analysis showed fairly uniform dispersion of dual size SiC particles in A357 matrix with good interfacial bonding. Compared to A357 alloy, the composites showed improvement in hardness, yield, and tensile strength. In particular, composite with 4 wt. % of fine and 2 wt. % of large SiC particles displayed the highest tensile strength while composite with 4 wt. % of large and 2 wt. % of fine SiC particles exhibited high hardness and wear resistance among A357 alloy and dual particle size composites. The strengthening mechanisms that contributed to improvement in strength values were effective load transfer and dislocation strengthening due to thermal mismatch. © 2019 Elsevier B.V.
  • Item
    Failure Analysis of Cooling Tower Fan-Arm
    (Springer, 2020) Padasale, B.; Kumar, J.K.R.; Sondar, P.R.; Cadambi, S.; Hegde, S.R.
    This work presents failure investigation of cooling tower fan-arms commissioned in a chemical processing plant. The analysis aims at understanding the mechanism and root-cause of the failure. The investigation involves site visits, microstructural analysis, fracture surface analysis, hardness measurements, numerical stress analysis and experimental simulation. Work concludes that the fan-arms failed due to the lack of post-weld heat treatment, which caused localized stress-corrosion and pitting at critical locations that served as crack initiation sites. Fatigue loading condition and presence of residual stresses at the weld enabled easy propagation of cracks that led to recurring premature failure. Based on the root-cause and the mechanism identified in this analysis, proper pre-heating and post-weld heat treatment is recommended to relieve the residual stresses at the critical locations and thus to avoid/minimize such recurring failures in future. © 2020, ASM International.
  • Item
    Premature failure of superheater tubes in a fertilizer plant
    (Elsevier Ltd, 2021) Dsilva, P.C.; Bhat, S.; Banappanavar, J.; Kodancha, K.G.; Hegde, S.R.
    This work presents an unique premature failure of steam superheater tubes in a fertilizer plant. The heat exchanger tube bundle made of SA 213 grade T11 steel suffered from wall thinning in the vicinity of baffles causing reduction in wall thickness of the tubes leading to perforation and leakage of steam from the tube-side into the shell-side during service. The work presents details of metallurgical failure analysis involving: site inspection, visual inspection, chemical analysis, X-Ray diffraction, microstructural analysis, and computational fluid dynamics analysis. The qualitative and quantitative chemical analyses and X-Ray diffraction carried out on superheater residue followed by microstructural analysis of failed tubes confirmed that the tubes suffered from aggressive corrosion attack at certain locations due to hot flue gas carrying alkaline salts and refractory fines. To understand the mechanism of thinning and the reasons for the tube bundle failure only at certain locations, a detailed CFD analysis was carried out on model of the heat exchanger which simulated the flow pattern of the hot gas. The analysis comprehensively demonstrates that the hot gas carrying both corrosive and erosive species caused erosion-corrosion of the tubes in the vicinity of tube-baffle junction that lead to wall thinning and subsequent failure of the tube bundle. Suitable remedial measures are suggested to minimize such failures in future. © 2020 Elsevier Ltd
  • Item
    Catastrophic failure of urea prill-tower fan
    (Elsevier Ltd, 2021) Hegde, S.R.; Rakshan Kumar, J.K.; Sondar, P.R.; Dsilva, P.C.
    This work presents failure investigation of a prill-tower fan that was in service for about 20 years in a urea plant. All the fan-blades and the plummer blocks fractured catastrophically during the plant-operation, shocked the plant personnel, and caused a huge shutdown loss. Standard failure analysis procedure involving: site visit, visual inspection, microstructural analysis, fracture analysis, analytical stress calculation and FEM analysis was followed. The investigation confirms that the fan-blades having numerous dents and nicks were operating in a mild corrosive atmosphere of ammonium hydroxide. The fracture analysis suggests that a pre-existing dent on the trailing edge of a blade corroded to form a pre-crack that aligned perpendicular to the long axis of the blade. When the pre-crack grew to a critical size, a small chunk of the blade fractured from the vicinity and ejected towards the blade-tip by centrifugal force. Because of confined space around the fan and limited blade-tip clearance, this triggered a chain reaction of blade fracture and rattled the entire array of fan-blades. The analysis establishes that the plummer blocks failed due to mechanical imbalance of the fan-shaft caused by the blade failure. The investigation concludes that presence of dents and nicks on the fan-blades is the root-cause for this catastrophic failure. Grinding-off of the surface defects to eliminate stress raisers is recommended for averting such a failure in future. © 2020 Elsevier Ltd