Walunj, A.Sathyabhama, A.2026-02-062018IOP Conference Series: Materials Science and Engineering, 2018, Vol.402, 1, p. -17578981https://doi.org/10.1088/1757-899X/402/1/012081https://idr.nitk.ac.in/handle/123456789/31641Experimental study of pool boiling heat transfer from the rough surface at pressure 1 bar, 5 bar and 10 bar is presented. Experiments are carried on 20 mm diameter copper sample at saturated condition of distilled water. Unidirectional scratches are made by different grit sandpaper. The surface roughness value R<inf>a</inf> is varied from 0.106 μm to 4.03 μm. The effect of R<inf>a</inf> on heat transfer at different pressure is reported. The variation in heat transfer coefficient with the heat flux for samples of different R<inf>a</inf> is also examined. The predicted critical heat flux (CHF) by Kim's model is found to in good agreement with present experimental values with mean absolute error of 12.06%. © Published under licence by IOP Publishing Ltd.and heat transfer coefficientcritical heat fluxpool boilingSurface roughnessInfluence of surface roughness on pool boiling heat transfer