Design of modified complementary terminal sliding mode controller for wind turbine at region II using a two-mass model

dc.contributor.authorRAJENDRAN, S.
dc.contributor.authorJena, D.
dc.contributor.authorDiaz-D, M.
dc.contributor.authorRodríguez, J.
dc.date.accessioned2026-02-03T13:21:05Z
dc.date.issued2024
dc.description.abstractMechanical loads impact the life span of a wind turbine; therefore, the reduction of transient loads in the drive train has gained more emphasis during the design of the controller for power extraction. The trade-off between power extraction and load reduction on the drive train has become a critical concern for wind turbines. Existing control approaches improve energy extraction and impose a more significant transient load on the drive train. Therefore, to address the above issue, a modified complementary terminal sliding mode controller is proposed in this study for wind turbines at below-rated wind speeds. The performance of both the proposed and existing controllers has been tested with a 600 kW FAST simulator. Moreover, each controller has been examined using different wind spectral models, such as Kaimal, Von Karman, Smooth-Terrain, and NWTCUP. The turbulent intensities of these models varied from 5% to 25%, and average wind speeds ranged from 7 m/s to 8.5 m/s. A dSPACE 1202 board was used to test the efficacy of the proposed controller in real-time. This analysis indicates that the proposed controller reduces the transient load by 11.98% and the control input by 9.57% compared to the complementary terminal sliding mode controller. Additionally, the proposed controller improves the energy capture by 1.18%. Finally, this analysis shows that the proposed approach can enhance overall performance and capture maximum power at below-rated wind speeds compared to existing control schemes. © 2024 The Authors
dc.identifier.citationResults in Engineering, 2024, 24, , pp. -
dc.identifier.urihttps://doi.org/10.1016/j.rineng.2024.103026
dc.identifier.urihttps://idr.nitk.ac.in/handle/123456789/20793
dc.publisherElsevier B.V.
dc.subjectRailroads
dc.subjectBelow-rated wind speed
dc.subjectComplementary terminal sliding mode controller
dc.subjectDrive train
dc.subjectEnergy extraction
dc.subjectFAST simulator
dc.subjectPower extraction
dc.subjectRated wind speed
dc.subjectSliding mode controller
dc.subjectTerminal sliding mode
dc.subjectTransient load
dc.subjectWind turbines
dc.titleDesign of modified complementary terminal sliding mode controller for wind turbine at region II using a two-mass model