Design of modified complementary terminal sliding mode controller for wind turbine at region II using a two-mass model
| dc.contributor.author | RAJENDRAN, S. | |
| dc.contributor.author | Jena, D. | |
| dc.contributor.author | Diaz-D, M. | |
| dc.contributor.author | Rodríguez, J. | |
| dc.date.accessioned | 2026-02-03T13:21:05Z | |
| dc.date.issued | 2024 | |
| dc.description.abstract | Mechanical loads impact the life span of a wind turbine; therefore, the reduction of transient loads in the drive train has gained more emphasis during the design of the controller for power extraction. The trade-off between power extraction and load reduction on the drive train has become a critical concern for wind turbines. Existing control approaches improve energy extraction and impose a more significant transient load on the drive train. Therefore, to address the above issue, a modified complementary terminal sliding mode controller is proposed in this study for wind turbines at below-rated wind speeds. The performance of both the proposed and existing controllers has been tested with a 600 kW FAST simulator. Moreover, each controller has been examined using different wind spectral models, such as Kaimal, Von Karman, Smooth-Terrain, and NWTCUP. The turbulent intensities of these models varied from 5% to 25%, and average wind speeds ranged from 7 m/s to 8.5 m/s. A dSPACE 1202 board was used to test the efficacy of the proposed controller in real-time. This analysis indicates that the proposed controller reduces the transient load by 11.98% and the control input by 9.57% compared to the complementary terminal sliding mode controller. Additionally, the proposed controller improves the energy capture by 1.18%. Finally, this analysis shows that the proposed approach can enhance overall performance and capture maximum power at below-rated wind speeds compared to existing control schemes. © 2024 The Authors | |
| dc.identifier.citation | Results in Engineering, 2024, 24, , pp. - | |
| dc.identifier.uri | https://doi.org/10.1016/j.rineng.2024.103026 | |
| dc.identifier.uri | https://idr.nitk.ac.in/handle/123456789/20793 | |
| dc.publisher | Elsevier B.V. | |
| dc.subject | Railroads | |
| dc.subject | Below-rated wind speed | |
| dc.subject | Complementary terminal sliding mode controller | |
| dc.subject | Drive train | |
| dc.subject | Energy extraction | |
| dc.subject | FAST simulator | |
| dc.subject | Power extraction | |
| dc.subject | Rated wind speed | |
| dc.subject | Sliding mode controller | |
| dc.subject | Terminal sliding mode | |
| dc.subject | Transient load | |
| dc.subject | Wind turbines | |
| dc.title | Design of modified complementary terminal sliding mode controller for wind turbine at region II using a two-mass model |