Osteoarthritis is a severe and progressive disorder that affects the knee joint due to
cartilage degradation from daily rigours activities. Articular cartilage is more
susceptible to knee arthritis compared with other soft tissues. Hence, understanding
degradation phenomena are more critical and require understanding the tissue's stress
fields. Experimental methods have limitations, such as inaccessible cadaveric knees
and obtaining in-vivo data from intact and arthritic knees is difficult and imprecise.
Hence the numerical method is the most effective technique for understanding the
cartilage’s mechanical behaviours under different conditions. The cartilage
constituents make the cartilage geometrically and mechanically heterogeneous. A 3D
finite element knee joint model is used to compute the articular cartilage response
during multiple activities. Various material models are available to model the
heterogeneity of articular cartilage. Multiple constitutive models are compared for the
prediction of mechanical response. In addition, the influence of the inhomogeneous
distribution of collagen fiber in cartilage is investigated for intact and arthritic knee
kinematics cases.
In reality, the cartilage structure is heterogeneous, and the computational study shows
the importance of heterogeneity in the mechanical response of the knee joint.
Conventionally the knee implant-bearing material (UHMWPE) is homogeneous.
Incorporating the heterogeneous characteristics in the bearing material may help
enhance the implant's mechanical characteristics. The proposed model generates
property-modulated characteristics in the bearing material using gamma irradiation,
and the heterogeneous characteristics are incorporated into the knee implant.
UHMWPE's tribological and chemical characteristics are analysed experimentally, and
the wear rate and volume are calculated. The wear rate decreases as the radiation dose
increase to a particular level and then increases as the dose increases further. Compared
with the conventional technique, a reduction in wear rate for the material is observed
for the proposed technique. Also, the hardness of the UHMWPE is measured, and its
value increases as the irradiation dose increases.
Description
Keywords
Knee joint Articular cartilage, Material heterogeneity, Collagen fiber orientation, Gait cycle