Effect of current density during electrodeposition on microstructure and hardness of textured Cu coating in the application of antimicrobial Al touch surface

dc.contributor.authorAugustin, A.
dc.contributor.authorHuilgol, P.
dc.contributor.authorUdupa, K.R.
dc.contributor.authorBhat, K.U.
dc.date.accessioned2026-02-05T09:32:58Z
dc.date.issued2016
dc.description.abstractCopper is a well proven antimicrobial material which can be used in the form of a coating on the touch surfaces. Those coating can offer a good service as touch surface for very long time if only they possess good mechanical properties like scratch resistance and microhardness. In the present work the above mentioned mechanical properties were determined on the electrodeposited copper thin film; deposited on double zincated aluminium. During deposition, current density was varied from 2 A dm?2 to 10 A dm?2, to produce crystallite size in the range of 33.5 nm to 66 nm. The crystallite size was calculated from the X-ray peak broadening (Scherrer?s formula) which were later confirmed by TEM micrographs. The scratch hardness and microhardness of the coating were measured and correlated with the crystallite size in the copper coating. Both characteristic values were found to increase with the reduction in crystallite size. Reduced crystallite size (Hall–Petch effect) and preferred growth of copper films along (111) plane play a significant role on the increase in the hardness of the coating. Further, TEM analysis reveals the presence of nano-twins in the film deposited at higher current density, which contributed to a large extent to the sharp increase of coating hardness compared to the mechanism of Hall–Petch effect. The antimicrobial ability of the coated sample has been evaluated against Escherichia coli bacteria and which is compared with that of commercially available bulk copper using the colony count method. 94% of E. coli cells were died after six hours of exposure to the copper coated surface. The morphology of the copper treated cells was studied using SEM. © 2016 Elsevier Ltd
dc.identifier.citationJournal of the Mechanical Behavior of Biomedical Materials, 2016, 63, , pp. 352-360
dc.identifier.issn17516161
dc.identifier.urihttps://doi.org/10.1016/j.jmbbm.2016.07.013
dc.identifier.urihttps://idr.nitk.ac.in/handle/123456789/25906
dc.publisherElsevier Ltd
dc.subjectAluminum
dc.subjectAluminum coatings
dc.subjectBiomechanics
dc.subjectCoatings
dc.subjectCopper
dc.subjectCurrent density
dc.subjectElectrodeposition
dc.subjectElectrodes
dc.subjectEscherichia coli
dc.subjectHardness
dc.subjectMechanical properties
dc.subjectMetal coatings
dc.subjectMicrohardness
dc.subjectMicroorganisms
dc.subjectThin films
dc.subjectTransmission electron microscopy
dc.subjectAntimicrobial ability
dc.subjectAntimicrobial materials
dc.subjectCopper coatings
dc.subjectE. coli
dc.subjectElectrodeposited copper thin films
dc.subjectEscherichia coli bacteria
dc.subjectNano-twins
dc.subjectScratch hardness
dc.subjectCrystallite size
dc.subjectaluminum
dc.subjectcopper
dc.subjectnanocrystal
dc.subjectantiinfective agent
dc.subjectbiocompatible coated material
dc.subjectantibacterial activity
dc.subjectArticle
dc.subjectcurrent density
dc.subjecthardness
dc.subjectnonhuman
dc.subjectparticle size
dc.subjectpriority journal
dc.subjectscanning electron microscopy
dc.subjectsurface property
dc.subjecttransmission electron microscopy
dc.subjectX ray diffraction
dc.subjectchemistry
dc.subjectdrug effects
dc.subjectelectroplating industry
dc.subjectAnti-Infective Agents
dc.subjectCoated Materials, Biocompatible
dc.subjectElectroplating
dc.titleEffect of current density during electrodeposition on microstructure and hardness of textured Cu coating in the application of antimicrobial Al touch surface

Files

Collections