Power quality improvement in front-end hybrid AC-DC converter based on current injection technique
| dc.contributor.author | P, P. | |
| dc.contributor.author | Kalpana, R. | |
| dc.contributor.author | Singh, B. | |
| dc.contributor.author | Bhuvaneswari, G. | |
| dc.date.accessioned | 2026-02-06T06:38:39Z | |
| dc.date.issued | 2017 | |
| dc.description.abstract | This paper highlights the power quality issues and explains the remedial measures taken by means of hybrid frontend third harmonic current injection rectifiers. Here zig-zag transformer is used as the current injection device so that the advantages pertaining to zig-zag transformer is utilized effectively. The third harmonic current injection device along with the three-level boost converter at the output stage will increase the dc-link voltage. Also, the power quality is well improved using third harmonic current modulated front-end structure which is well appropriate to medium/higher power applications. The experimental prototype of hybrid front-end PFC rectifier is developed in the laboratory to validate the MATLAB simulation results. © 2017 IEEE. | |
| dc.identifier.citation | 2017 IEEE Transportation Electrification Conference, ITEC-India 2017, 2017, Vol.2018-January, , p. 1-5 | |
| dc.identifier.uri | https://doi.org/10.1109/ITEC-India.2017.8356959 | |
| dc.identifier.uri | https://idr.nitk.ac.in/handle/123456789/31807 | |
| dc.publisher | Institute of Electrical and Electronics Engineers Inc. | |
| dc.subject | Front-end rectifier | |
| dc.subject | PFC | |
| dc.subject | power quality | |
| dc.subject | THD | |
| dc.subject | third harmonic hybrid current injection | |
| dc.subject | three-level boost converter | |
| dc.subject | zig-zag transformer | |
| dc.title | Power quality improvement in front-end hybrid AC-DC converter based on current injection technique |