Computation of steady-state operating conditions of a DFIG-based wind energy conversion system considering losses

dc.contributor.authorKarthik, D.R.
dc.contributor.authorManjarekar, N.S.
dc.contributor.authorKotian, S.M.
dc.date.accessioned2026-02-04T12:26:29Z
dc.date.issued2023
dc.description.abstractIn this paper, steady-state operating conditions of a doubly fed induction generator (DFIG) are computed considering losses of grid-side (GS) filter. Two different cases are studied for steady-state initialization of the DFIG-based wind turbine systems (WTS). In the first case, active power (P) and reactive power (Q) at DFIG terminals are assumed to be known. In the other case wind speed (V<inf>w</inf>), Q is assumed to be known. Apart from considering losses of the DFIG and GS filter, both the cases also consider the non-unity power factor operation of the grid side converter (GSC). For the first case, steady-state operating conditions are calculated by iterative method as well as by non-iterative method. For the second case, iterative method is used to calculate steady-state operating conditions. Calculation of steady-state values of other subsystems of DFIG-based WTS like drive train, controller and network is also shown. The initial values calculated are validated and compared by performing modal analysis and time-domain simulations. © 2023, The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.
dc.identifier.citationElectrical Engineering, 2023, 105, 3, pp. 1825-1838
dc.identifier.issn9487921
dc.identifier.urihttps://doi.org/10.1007/s00202-023-01766-x
dc.identifier.urihttps://idr.nitk.ac.in/handle/123456789/21883
dc.publisherSpringer Science and Business Media Deutschland GmbH
dc.subjectAsynchronous generators
dc.subjectElectric fault currents
dc.subjectElectric power factor
dc.subjectEnergy conversion
dc.subjectModal analysis
dc.subjectReactive power
dc.subjectTime domain analysis
dc.subjectWind
dc.subjectWind power
dc.subjectDoubly fed induction generators
dc.subjectGrid-side filter
dc.subjectNon-iterative method
dc.subjectOperating points
dc.subjectSteady-state operating
dc.subjectSteady-state operating conditions
dc.subjectSteady-state operating point
dc.subjectTime-domain simulations
dc.subjectWind energy conversion
dc.subjectWind turbine systems
dc.subjectIterative methods
dc.titleComputation of steady-state operating conditions of a DFIG-based wind energy conversion system considering losses