Selective complexometric determination of palladium with sodium metabisulphite as releasing agent
Files
Date
2009
Authors
Shetty, P.
Shetty, A.N.
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
Sodium metabisulphite has been proposed as a selective releasing agent for the rapid and selective complexometric determination of palladium. Pd(II) present in a given sample solution is first complexed with excess of EDTA and the surplus EDTA is back titrated with standard zinc sulphate solution at pH 5-5.5 (acetic acid-sodium acetate buffer) using xylenol orange as indicator. Sodium metabisulphite solution is then added to displace EDTA quantitatively from the Pd-EDTA complex. The released EDTA is back titrated with standard zinc sulphate solution as before. The method works well in the concentration range 2-20 mg of Pd with a relative error ? 0.40% and relative standard deviation ? 0.65%. The method has been applied to the determination of palladium in catalysts, alloys and complexes.
Description
Keywords
Citation
Indian Journal of Chemical Technology, 2009, Vol.16, 3, pp.259-264