Genetic algorithm in location identification of AEPD source: Some aspects

No Thumbnail Available

Date

2013

Authors

Punekar, G.S.
Antony, D.
Bhavanishanker, T.
Nagamani, H.N.
Kishore, N.K.

Journal Title

Journal ISSN

Volume Title

Publisher

Abstract

Using the experimental data obtained from an Acoustic Emission Partial Discharge (AEPD) system, efforts are made to locate the source of Partial discharge (PD) with a transformer tank. The AEPD data with 8 sensors (available in the literature) is numerically experimented with a Genetic Algorithm, although minimum of 4 sensors only are necessary for identifying the location. With eight sensors, four sensors considered at a time, form 70 ( 8C4) combination of sensors. The effect, implication and usage of superfluous sensor data in identifying the location with GA is analyzed and reported. Results are compared with Newton's method. � 2013 IEEE.

Description

Keywords

Citation

2013 IEEE 1st International Conference on Condition Assessment Techniques in Electrical Systems, IEEE CATCON 2013 - Proceedings, 2013, Vol., , pp.386-390