Abstract

In this study, the effect of graded design in comparison to homogeneous cartilage material is investigated for contact pressure distribution in the human knee joint. Knee implants are assumed a homogeneous material. In reality, cartilages are not homogeneous, and to replicate the heterogeneity of cartilages, a graded design is proposed. Simulation results show improved contact pressure distribution in the knee joint due to the graded composition of cartilages. The results are helpful in designing a new class of implant materials. © 2021, The Korean Society of Mechanical Engineers and Springer-Verlag GmbH Germany, part of Springer Nature.

Description

Keywords

Citation

Journal of Mechanical Science and Technology , Vol. 35 , 3 , p. 1049 - 1054