Widely Tunable Bandwidth Ultra Low Power Continuous Time Filters for Biomedical Applications
Date
2020
Authors
M K, Jayaram Reddy.
Journal Title
Journal ISSN
Volume Title
Publisher
National Institute of Technology Karnataka, Surathkal
Abstract
This research intends to focus on filter architectures for bio-medical applications. The proposed filter architectures are designed to operate on
a supply voltage of 1.8 V in 0.18 µm standard CMOS process from UMC
technologies.
Initially, this thesis proposes a novel architecture for realizing very low
transconductance values with tunability. This transconductor architecture makes it possible to realize a fully differential filter without the need
of explicit common-mode feed back (CMFB) circuit. Using the proposed
transconductor a fourth-order, low pass Butterworth gm-C filter with tunable bandwidth has been designed for biomedical signal processing frontends. This novel filter architecure has two bandwidth tuning schemes,
a resistor based tuning (R-tuning) and a switched transconductor based
tuning (D-tuning). With these tuning techniques, the filter is made tunable in the range 30 mHz-100 Hz. The filter operating on 1.8 V supply is
found to offer a DR of 56 dB consuming a power of 1.14 µW. In terms of
Figure-of-Merit (FoM), the proposed filter is found to be on par with the
filters reported in literature.
This thesis also proposes a second-order low pass Butterworth filter with
tunable bandwidth capable of offering a dynamic range of 91.86 dB. The
proposed filter is based on a sub-threshold source follower. The main idea
is to exploit the strengths of sub-threshold source follower circuit, like low
noise, low output impedance, high linearity and low power. The transistor
bias currents are switched to enable the bandwidth tuning in the range 4
Hz - 100 Hz. A PTAT current reference circuit helps to keep the bandwidth
intact across process, voltage and temperature variations. In terms of noise
and dynamic range the reported filter is better than previous works found
from the literature. The filter consumes 25.9 nW making it a potential
candidate for portable biomedical applications.
Finally, this thesis proposes a scheme to enhance the output resistance of
a differential amplifier. A negative resistance is used to cancel the output
resistance of the differential amplifier. This inturn is achieved through a
transimpedance based loop. It is proved that the proposed scheme can
vgive a gain enhancement of about two folds (in dB) compared to the gain
of basic differential transconductor, without loss in linearity. An OTA
designed using this scheme is found to offer least sensitivity of gain boost
over output voltage swing across process corners, at nominal voltage and
temperature, when compared to other methods found in literature. A first
order filter is designed using the proposed ro enhanced OTA. The filter
offer cut-off frequency down to 0.5 Hz without any switching scheme, and
more significantly without the loss of DC gain.
Description
Keywords
Department of Electronics and Communication Engineering, Analog filter, Low cut-off frequency, Bio-medical, Source follower, High dynamic range, Conductance cancellation, Gain enhancement, High gain OTA