Assessment of thermally deteriorated concrete by drilling resistance test and sound level

dc.contributor.authorKulkarni, K.S.
dc.contributor.authorYaragal, S.C.
dc.contributor.authorBabu, Narayan, K.S.
dc.contributor.authorVardhan, H.
dc.date.accessioned2020-03-31T08:19:19Z
dc.date.available2020-03-31T08:19:19Z
dc.date.issued2017
dc.description.abstractConcrete being the most versatile and widely used construction material finds application in varied range of structures. Many of these like chimneys, furnaces and reactors have to sustain high temperatures and perhaps all structures have to perform at elevated temperatures in the event of fire accidents. Concrete at elevated temperatures undergoes changes in its physical structure and chemical composition and loses its strength characteristics. Need for quick assessment of fire damaged concrete for strength characteristics, has motivated this work, which explores the potential of drilling resistance test on concrete as a Non Destructive Testing (NDT) tool. Drilling times, penetration depths and sound level measurement while drilling have been recorded and analysed to provide monograms that are handy as reckoners in failure forensics. 2017, Pleiades Publishing, Ltd.en_US
dc.identifier.citationRussian Journal of Nondestructive Testing, 2017, Vol.53, 11, pp.805-815en_US
dc.identifier.urihttps://idr.nitk.ac.in/handle/123456789/10488
dc.titleAssessment of thermally deteriorated concrete by drilling resistance test and sound levelen_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
12.Assessment of Thermally.pdf
Size:
1.07 MB
Format:
Adobe Portable Document Format