Performance Improvement of M-Class Phasor Measurement Unit (PMU) using Hamming and Blackman Windows
No Thumbnail Available
Date
2020
Authors
Hampannavar S.
Teja C.B.
Swapna M.
Kumar U.R.Y.
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
According to the standard C37.118.1, Phasor Measurement Units (PMU) can be broadly classified into two classes: Measurement (M) and Performance (P), where P-Class is used when faster output latency is required and M-Class is used for measurement applications which requires high precision. The standard presents Hamming window as a reference algorithm for M-Class PMU whereas, in this paper we use Blackman window algorithm. The performance of M-Class PMU is analyzed with both the algorithms by taking two case studies in which input given to the PMU is contaminated with different levels of harmonics, inter-harmonics and frequency ramps in each case and it is found that, the errors in frequency and rate of change of frequency (ROCOF) measured by PMU are reduced by a factor of >100 with the Blackman window algorithm when compared to a Hamming window algorithm (which is specified in the standard). © 2020 IEEE.
Description
Keywords
Citation
2020 IEEE International Conference on Power Electronics, Smart Grid and Renewable Energy, PESGRE 2020 , Vol. , , p. -