The wind tunnel experiments were conducted over a solid/perforated plate with a long splitter plate in its plane of symmetry. The effect of varied level of perforation of the normal plate on the behaviour of two dimensional separation bubble was studied. The mean velocity and surface mean pressure distributions were also measured after preliminary flow visualization studies. The normal plate perforation levels used are 0%, 10%, 20%, 30%, 40% and 50%. The Reynolds number based on step height was varied from 4 × 103 to 1.2 × 104. Mean pressures were found to be strongly dependent on perforation level of the normal plate. The shape and size of the bubble vary with different perforated normal plate that is to say, the bubble gels reduced both in height and length upto 30% perforation level. For higher perforation of the normal plate, the bubble is completely swept out. © 2002 Taylor & Francis Group, LLC.

dc.contributor.authorYaragal, S.C.
dc.contributor.authorGovind Ram, H.S.
dc.contributor.authorMurthy, K.K.
dc.date.accessioned2026-02-05T11:00:30Z
dc.date.issuedAn experimental investigation of mean flow field behind perforated plates on a flat surface
dc.description.abstract2002
dc.identifier.citationISH Journal of Hydraulic Engineering, 2002, 8, 2, pp. 34-43
dc.identifier.issn9715010
dc.identifier.urihttps://doi.org/10.1080/09715010.2002.10514714
dc.identifier.urihttps://idr.nitk.ac.in/handle/123456789/27999
dc.subjectExperimental investigation
dc.subjectMean flow field
dc.subjectPerforated plates
dc.subjectRecirculating flows
dc.subjectTwo-dimensional bubble
dc.titleThe wind tunnel experiments were conducted over a solid/perforated plate with a long splitter plate in its plane of symmetry. The effect of varied level of perforation of the normal plate on the behaviour of two dimensional separation bubble was studied. The mean velocity and surface mean pressure distributions were also measured after preliminary flow visualization studies. The normal plate perforation levels used are 0%, 10%, 20%, 30%, 40% and 50%. The Reynolds number based on step height was varied from 4 × 103 to 1.2 × 104. Mean pressures were found to be strongly dependent on perforation level of the normal plate. The shape and size of the bubble vary with different perforated normal plate that is to say, the bubble gels reduced both in height and length upto 30% perforation level. For higher perforation of the normal plate, the bubble is completely swept out. © 2002 Taylor & Francis Group, LLC.