A new colorimetric chemosensors for Cu2+ and Cd2+ ions detection: Application in environmental water samples and analytical method validation
| dc.contributor.author | Tekuri, V. | |
| dc.contributor.author | Trivedi, D.R. | |
| dc.date.accessioned | 2026-02-05T09:32:20Z | |
| dc.date.issued | 2017 | |
| dc.description.abstract | A new heterocyclic thiophene-2-caboxylic acid hydrazide based chemosensor R1 to R4 were designed, synthesized and characterized by various spectroscopic techniques like FT-IR, UV-Vis, 1H NMR, 13C NMR, Mass and SC-XRD. The chemosensor R3 showed a significant color change from colorless to yellow in the presence of Cu2+ ions and chemosensor R4 showed a significant color change from colorless to yellow in the presence of Cd2+ ions over the other tested cations such as Cr3+, Mn2+, Fe2+, Fe3+, Co2+, Ni2+, Zn2+, Ag2+, Al3+, Pb2+, Hg2+, K+, Ca2+ and Mg2+. The high selective and sensitivity of R3 towards Cu2+ and R4 towards Cd2+ ions was confirmed by UV-Vis spectroscopic study. The R3 showed a red shift in the presence of Cu2+ ions by ??<inf>max</inf> 67 nm and R4 showed a red shift in the presence of Cd2+ ions by ??<inf>max</inf> 105 nm in the absorption spectrum. The binding stoichiometric ratio of the complex between R3 - Cu2+ and R4 - Cd2+ ions have been found to be 1:1 using the B-H plot. Under optimized experimental conditions, the R3 and R4 exhibits a dynamic linear absorption response range, from 0 to 50 ?M for Cu2+ ions and 0 to 30 ?M for Cd2+ ions, with the detection limit of 2.8 × 10?6 M for Cu2+ and 2.0 × 10?7 M for Cd2+ ions. The proposed analytical method for the quantitative determination of Cu2+ and Cd2+ ions was validated and successfully applied for the environmental samples with good precision and accuracy. © 2017 Elsevier B.V. | |
| dc.identifier.citation | Analytica Chimica Acta, 2017, 972, , pp. 81-93 | |
| dc.identifier.issn | 32670 | |
| dc.identifier.uri | https://doi.org/10.1016/j.aca.2017.03.035 | |
| dc.identifier.uri | https://idr.nitk.ac.in/handle/123456789/25599 | |
| dc.publisher | Elsevier B.V. | |
| dc.subject | Absorption spectroscopy | |
| dc.subject | Color | |
| dc.subject | Colorimetry | |
| dc.subject | Doppler effect | |
| dc.subject | Physiology | |
| dc.subject | Spectroscopic analysis | |
| dc.subject | Synthesis (chemical) | |
| dc.subject | Analytical method validation | |
| dc.subject | Association constant | |
| dc.subject | Colorimetric chemosensor | |
| dc.subject | Environmental water samples | |
| dc.subject | Experimental conditions | |
| dc.subject | Quantitative determinations | |
| dc.subject | Spectroscopic studies | |
| dc.subject | Spectroscopic technique | |
| dc.subject | Ions | |
| dc.subject | cadmium | |
| dc.subject | cupric ion | |
| dc.subject | absorption spectroscopy | |
| dc.subject | Article | |
| dc.subject | association constant | |
| dc.subject | binding affinity | |
| dc.subject | colorimetry | |
| dc.subject | controlled study | |
| dc.subject | infrared spectroscopy | |
| dc.subject | limit of detection | |
| dc.subject | limit of quantitation | |
| dc.subject | linear system | |
| dc.subject | measurement accuracy | |
| dc.subject | measurement precision | |
| dc.subject | priority journal | |
| dc.subject | process optimization | |
| dc.subject | quantitative analysis | |
| dc.subject | stoichiometry | |
| dc.subject | structure analysis | |
| dc.subject | ultraviolet spectroscopy | |
| dc.subject | validation process | |
| dc.subject | water sampling | |
| dc.title | A new colorimetric chemosensors for Cu2+ and Cd2+ ions detection: Application in environmental water samples and analytical method validation |