Effect of employing metal cored filler wire for single v butt joint welding of Ti-Nb microalloyed 800MPa steels
No Thumbnail Available
Date
2020
Authors
John M.
Peraka A.K.
Kuruveri U.B.
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
Ti-Nbmicroalloyed 800 MPa steels are an important group of advanced high strength steels being developed for automobile applications. One requirement for practical application is the development of a reliable welding process. P-GMAW technique with synergic control and metallic cored filler wires are the advances in the domain of GMAW technique. These are used in welding Ti-Nb steel. The results indicate that use of metal cored wire increased penetration, reduces spatter marginally reduces HAZ width, increases weld hardness, and UTS is marginally higher. In both samples fracture took place in the HAZ, indicating it is the weakest domain in the welded system. Overall results indicate that the use of metal cored wire is beneficial compared to the solid wire during P-GMAW. © 2020 Author(s).
Description
Keywords
Citation
AIP Conference Proceedings , Vol. 2236 , , p. -