Widely tunable low-pass gm - C filter for biomedical applications

dc.contributor.authorKrishna, J.R.M.
dc.contributor.authorLaxminidhi, T.
dc.date.accessioned2020-03-31T08:48:13Z
dc.date.available2020-03-31T08:48:13Z
dc.date.issued2019
dc.description.abstractThis study presents a fourth-order, low-pass Butterworth transconductor�capacitor gm ? C filter with tunable bandwidth for biomedical signal processing front-ends. An architecture has been proposed for realising very low transconductance values with tunability. This transconductor architecture makes it possible to realise a fully differential filter without the need for explicit common-mode feedback circuit. The filter has two tuning schemes, a resistor-based tuning (Rtuning) and a switched transconductor-based tuning (D-tuning). With R-tuning, the bandwidth is adjustable between 1 and 70 Hz and with D-tuning, the tuning range is 30 mHz�100 Hz. The filter has been designed in united microelectronics corporation (UMC) 0.18 �m complementary metal�oxide�semiconductor process. In terms of figure-of-merit, the proposed filter is found to be on par with the filters reported in the literature. � The Institution of Engineering and Technology 2018en_US
dc.identifier.citationIET Circuits, Devices and Systems, 2019, Vol.13, 2, pp.239-244en_US
dc.identifier.uri10.1049/iet-cds.2018.5002
dc.identifier.urihttps://idr.nitk.ac.in/handle/123456789/13587
dc.titleWidely tunable low-pass gm - C filter for biomedical applicationsen_US
dc.typeArticleen_US