Dynamic Soil Structure Interaction of a High-Rise Building Resting over a Finned Pile Mat
| dc.contributor.author | Bariker, P. | |
| dc.contributor.author | Kolathayar, S. | |
| dc.date.accessioned | 2026-02-04T12:27:36Z | |
| dc.date.issued | 2022 | |
| dc.description.abstract | High-rise building safety is generally supported by pile-mat systems. They must be sturdy enough to withstand potential lateral loads brought on by earthquakes, wind, dredging, and machine vibrations, in addition to increased axial loads. An innovative piled-mat foundation system is required to deal with these impacts because standard pile foundation systems only have lateral capacities that are 10% of their axial capacities. This study aims to reduce the damage caused by seismic impacts on high-rise buildings using shear walls supported by piled mats, thereby minimizing vibrations within the structure. Compared with conventional pile systems, the finned-pile foundation is a proven method that can withstand a 65% to 80% higher lateral load; hence, a series of SSI analyses were performed on a 25-story high-rise building, with the shear wall resting on a finned-pile mat (FP-Mat), under a far-field earthquake excitation, using ABAQUS software. The seismic responses were studied by performing a time–history analysis on the FP-Mat, with varying fin-lengths (L<inf>f</inf>) of 0.2L<inf>p</inf>, 0.4L<inf>p</inf>, 0.6L<inf>p</inf>, and 0.8L<inf>p</inf>, which was compared with an analysis of a conventional piled-mat (RP-Mat). The seismic responses for RP-Mat and FP-Mats were studied with peak-acceleration, maximum horizontal displacement, and inter-story drifts acting as the damage parameters. The provision of FP-Mats significantly reduced the vibrations and seismic effects on the building, and as the fin-length increased, the vibrations and seismic effects reduced further. The drifting bound was also reduced as the fin-length increased. The optimum fin-length for FP-Mats is suggested to be 0.6L<inf>p</inf> in terms of seismic performance and construction efficiency. This study helps one understand the seismic behaviors of high-rise buildings resting on finned pile mats. © 2022 by the authors. | |
| dc.identifier.citation | Infrastructures, 2022, 7, 10, pp. - | |
| dc.identifier.uri | https://doi.org/10.3390/infrastructures7100142 | |
| dc.identifier.uri | https://idr.nitk.ac.in/handle/123456789/22375 | |
| dc.publisher | MDPI | |
| dc.subject | fin-length | |
| dc.subject | finned-pile mat | |
| dc.subject | high-rise building | |
| dc.subject | inter-story drift | |
| dc.subject | soil structure interaction | |
| dc.subject | time-history analysis | |
| dc.title | Dynamic Soil Structure Interaction of a High-Rise Building Resting over a Finned Pile Mat |