Indirect complexometric determination of mercury(II) using 3-acetyl-2-thiohydantoin as a selective masking agent

dc.contributor.authorKarthikeyan, J.
dc.contributor.authorParameshwara, P.
dc.contributor.authorNityananda Shetty, A.N.
dc.date.accessioned2026-02-05T09:36:53Z
dc.date.issued2008
dc.description.abstractA complexometric method for the determination of mercury(II) in presence of other metal ions is described based on the selective masking action of 3-acetyl-2-thiohydantoin towards mercury(II). Mercury(II) present in a given sample solution is first complexed with an excess of EDTA and the unreacted EDTA is titrated against standard lead nitrate solution at pH 5-6 (hexamine buffer) using xylenol orange as the indicator. A 0.5% solution of 3-acetyl-2- thiohydantoin is then added to displace EDTA from the Hg(II)-EDTA complex. The released EDTA is estimated. Reproducible and accurate results are obtained for 3.96-80 mg of mercury(II) with relative error less than ± 0.25% and coefficient of variation not more than 0.38%. The effects of various ions were studied. The method is used or the analysis of mercury in its synthetic mixtures of ions and in complexes.
dc.identifier.citationIndian Journal of Chemical Technology, 2008, 15, 5, pp. 493-496
dc.identifier.issn0971457X
dc.identifier.urihttps://idr.nitk.ac.in/handle/123456789/27712
dc.subject3-Acetyl-2-thiohydantoin
dc.subjectComplexometric titration
dc.subjectMercury(II)
dc.titleIndirect complexometric determination of mercury(II) using 3-acetyl-2-thiohydantoin as a selective masking agent