Faculty Publications
Permanent URI for this communityhttps://idr.nitk.ac.in/handle/123456789/18736
Publications by NITK Faculty
Browse
8 results
Search Results
Item Analytical computation of thermodynamic performance parameters of actual vapour compression refrigeration system with R22, R32, R134a, R152a, R290 and R1270(EDP Sciences edps@edpsciences.com, 2018) Vali, S.S.; Setty, T.P.; Babu, A.The present work focuses on analytical computation of thermodynamic performance of actual vapour compression refrigeration system by using six pure refrigerants. The refrigerants are namely R22, R32, R134a, R152a, R290 and R1270 respectively. A MATLAB code is developed to compute the thermodynamic performance parameters of actual vapour compression system such as refrigeration effect, compressor work, COP, power per ton of refrigeration, compressor discharge temperature and volumetric refrigeration capacity at condensing and evaporating temperatures of 54.4oC and 7.2oC respectively. Analytical results exhibited that COP of both R32 and R134a are 15.95% and 11.71% higher among the six investigated refrigerants. However R32 and R134a cannot be replaced directly into R22 system. This is due to their higher compressor discharge temperature and poor volumetric capacity respectively. The discharge temperature of both R1270 and R290 are lower than R22 by 20-26oC. Volumetric refrigeration capacity of R1270 (3197 kJ/m3) is very close to that of volumetric capacity of R22 (3251 kJ/m3). Both R1270 and R290 shows good miscibility with R22 mineral oil. Overall R1270 would be a suitable ecofriendly refrigerant to replace R22 from the stand point of ODP, GWP, volumetric capacity, discharge temperature and miscibility with mineral oil although its COP is lower. © The Authors, published by EDP Sciences, 2018.Item Performance computation of window air conditioner with very low GWP near azeotropic refrigerant mixtures as a drop in Substitutes to R22(EDP Sciences edps@edpsciences.com, 2018) Vali, S.S.; Setty, T.P.; Babu, A.The principal objective of the present study is to compute the thermodynamic performance of window air conditioner based on standard vapour compression refrigeration cycle using R22, R407C and nineteen refrigerant mixtures. In this work nineteen R290/R1270 blends at different compositions are developed. A MATLAB code is developed to compute the thermodynamic performance parameters of all the studied refrigerants at condensing and evaporating temperatures of 54.4°C and 7.2°C respectively. The performance parameters are cooling effect, compressor work, COP, compressor discharge temperature, power per ton of refrigeration and volumetric cooling capacity respectively. Analytical results revealed that COP of new binary mixture R290/R1270 (90/10 by mass %) is 2.82% higher among R22, R407C and nineteen studied refrigerants. Energy required by the compressor per ton of refrigeration for R290/R1270 (90/10 by mass %) is 2.73% lower among R22, R407C and nineteen studied fluids. The discharge temperature of the compressor for all the nineteen investigated blends are reduced by 6.0-8.9oC compared to R22. Overall thermodynamic performance of window air conditioner with R290/R1270 (90/10 by mass %) is better than R22 with significant savings in energy consumption and hence it is an energy efficient ecofriendly refrigerant mixture as a drop in substitute to R22. © The Authors, published by EDP Sciences, 2018.Item Theoretical Evaluation of Energy Performance of a Vapour Compression Refrigeration System Using Sustainable Refrigerants(Springer, 2020) Vali, S.V.; Ashok Babu, T.P.The chief goal of this present investigation is to evaluate performance parameters of various sustainable refrigerants as R22 alternatives. In this investigation apart from R290, R134a and R22, twelve mixture refrigerants were developed at various composition. Results showed that energy efficiency ratio (EER) of mixture refrigerant MR40 (R290/R134a 95/5 in mass%) (4.546) stood greatest among twelve investigated alternatives and it was closer to the EER of R22 (4.602). Compressor discharge temperature of MR40 was lower than R22 by 16.020C. Volumetric refrigeration capacity of MR40 (3424 kJ/m3) was relatively lesser than R22 (3801 kJ/m3). Power spent per ton of refrigeration (PPTR) of MR40 (0.773 kW/TR) stood lowest among twelve investigated alternatives and it was fairly greater than R22 (0.764 kW/TR). Global warming potential (GWP100) of MR40 (68) was very low compared to R22 (1760). Overall, performance of MR40 was closer to R22, when compared with all the twelve investigated alternatives, and hence, it might be treated as a suitable replacement to refrigerant R22. © 2020, Springer Nature Singapore Pte Ltd.Item Analytical computation of thermodynamic performance of various new eco-friendly alternative refrigerants applicable for air conditioners(Springer Science and Business Media Deutschland GmbH info@springer-sbm.com, 2021) Vali, S.V.; Ashok Babu, T.P.; Mahapatra, D.; Saboor, S.; Gorantla, K.K.; Sai Siva Subramanyam, V.The objective of the present investigation is to do the theoretical thermodynamic analysis of various new eco-friendly R22 substitutes used in vapour compression refrigeration (VCR) cycle. In this work, nine mixture refrigerants were considered at different compositions. Thermodynamic properties of all the considered refrigerants were developed and the same properties were used in the performance analysis of alternative refrigerants. Standard VCR cycle was considered for the thermodynamic assessment of alternative refrigerants. The working conditions considered are expressed as Te = 7.2 °C, Tk = 54.4 °C, ΔTsup = 11.1 °C and ΔTsub = 8.3 °C, respectively. Results revealed that the COP of mixture refrigerant MR20 (R600a/R134a/R1270 5/47.5/47.5 in mass%) was 2.02% higher than the COP of R22 and other nine investigated refrigerants. Discharge temperature of compressor obtained for MR20 was 11.79 °C lower compared to that of R22. Compressor power obtained for MR20 was 1.96% lower than that of R22. Volumetric refrigeration capacity obtained for MR20 was relatively closer to that of R22. GWP100 of MR20 (619) was lower compared to the GWP100 of R22 (1760). Overall, the performance of mixture refrigerant MR20 was better compared to all the considered R22 alternatives, and therefore it might be an appropriate candidate to replace R22 used in air conditioners. © Springer Nature Singapore Pte Ltd 2021.Item Thermodynamic performance analysis and flammability study of various new ozone friendly non azeotropic refrigerant mixtures as alternatives to replace R22 used in residential air conditioners(International Information and Engineering Technology Association info@iieta.org, 2018) Vali, S.V.; Ashok Babu, T.P.A.The present study investigates the theoretical thermodynamic performance analysis and flammability study of various new ozone friendly refrigerants as replacements to R22. In this work, five non azeotropic refrigerant blends comprising of R152a, R134a, R32, R290 and R1270, at various compositions were developed. Flammability study of all the five refrigerant mixtures considered were carried out by using Refrigerant Flammability (RF) number. The cycle followed during the performance investigation of refrigerants was the actual vapour compression refrigeration cycle. Thermodynamic performance characteristics of all the five investigated refrigerants were compared with the baseline refrigerant R22. Theoretical results showed that COP of refrigerant M40 was 0.51% higher, compared to R22 and the five refrigerants studied. Compressor discharge temperature of M40 was lowered by 11.6°C compared to R22. Power consumed to produce per ton of refrigeration of M40 was 0.52% lower, compared to R22 and the five refrigerants considered. Heat transfer rate through the condenser for M40 was 3.66% higher than R22. Volumetric refrigeration capacity of M40 was the highest among the five studied refrigerants and it was very close to the volumetric capacity of R22. Flammability analysis revealed that all the five investigated refrigerant mixtures were classified into the weakly flammable category. Overall, the thermodynamic performance of new ternary blend M40 (R32/R134a/R1270 5/60/35 by mass percentage) was higher than R22 with reasonable saving in power consumption and hence, M40 is a viable candidate to replace R22. © 2018 International Information and Engineering Technology Association. All Rights Reserved.Item Thermodynamic analysis of window air conditioner using sustainable refrigerant R290/RE170 and R1270/RE170 blends as substitutes to refrigerant R22(International Information and Engineering Technology Association info@iieta.org, 2019) Vali, S.V.; Setty, A.B.T.P.The present work emphasis on theoretical computation of thermodynamic performance of window air conditioner using various sustainable R290/RE170 and R1270/RE170 refrigerant mixtures as substitutes to R22. In this work, apart from R407C, twelve new binary mixtures comprising of R290, R1270 and RE170 at various compositions were developed. And also in this investigation, a MATLAB code was developed to compute the thermodynamic performance characteristics of various considered R22 alternatives at Tk=54.4 0C and Te=7.2 °C. The various performance characteristics computed are mass flow rate, refrigeration effect, compressor work, coefficient of performance (COP), pressure ratio, compressor discharge temperature, power consumed per ton of refrigeration, condenser heat rejection and volumetric cooling capacity. Results showed that the COP of refrigerant mixture RM7 (R1270/RE170 95/5 by mass %) was the highest among twelve refrigerants studied and it was 0.23 % higher than R22. Pressure ratio of RM7 (3.174) was 7.49 % lower than that of R22 (3.431). Compressor discharge temperature of all the twelve investigated refrigerants was lower in the range of 9.35 0C to 17.15 0C when compared with R22. Power consumed per ton of refrigeration of RM7 was 0.27 % lower than that of R22. Volumetric cooling capacity of RM7 (3833 kJ/m3) was very close to that of R22 volumetric capacity (3863 kJ/m3). Heat transfer through condenser of RM7 (6.372 kW) was similar to that of R22 (6.377 kW). Overall, thermodynamic performance of RM7 matches well with the performance of base line refrigerant R22 and hence, refrigerant RM7 can be considered as sustainable alternative to R22 used in air conditioners. © 2019 International Information and Engineering Technology Association. All rights reserved.Item Theoretical thermodynamic performance assessment of various environment-friendly novel refrigerants used in refrigeration systems(SAGE Publications Ltd info@sagepub.co.uk, 2020) Vali, S.S.; Ashok Babu, T.P.A.The present investigation focuses on theoretical performance of various new environment-friendly refrigerant mixtures as substitutes to high global warming potential refrigerant R22. In this investigation, 34 refrigerants were considered at various composition. In this work, both complex vapor compression cycle (actual cycle) and standard vapor compression cycle (ideal cycle) was considered for the performance assessment of refrigerants. Vital studies such as flammability, toxicity, and environmental impact of various novel refrigerants were also carried out in this study. Results obtained from actual cycle showed that the coefficient of performance of refrigerant mixture RM40 (R1270/R134a 90/10 in mass %) (2.728) was the greatest among 34 investigated alternatives and it was closer to the coefficient of performance of R22 (2.770). Compressor discharge temperature of RM40 was 13.36 ? lower when compared with R22. Volumetric refrigeration capacity of RM40 (3335 kJ/m3) was slightly higher than that of R22 (3297 kJ/m3). Power spent per ton of refrigeration of RM40 (1.288 kW/TR) was marginally higher than that of R22 (1.269 kW/TR). Global warming potential (GWP100) of RM40 (133) was very low compared to the GWP100 of R22 (1760). Total equivalent warming index (environmental impact) of RM40 was 5.61% lower than R22. However, performance results obtained from standard cycle for various investigated refrigerants were better than actual cycle, since various losses occur were neglected in the standard cycle. Overall, thermodynamic performance of refrigerant mixture RM40 (R1270/R134a 90/10 in mass %) obtained from both actual and standard cycle was the highest among 34 investigated refrigerants and it was very closer to the performance of R22 and hence, it could be considered as an environment-friendly alternative to replace high GWP refrigerant R22 used in refrigeration systems. © IMechE 2019.Item Theoretical energy performance assessment and environmental impact of various new ozone-friendly refrigerants used in residential air conditioners(SAGE Publications Ltd, 2020) Vali, S.V.; Ashok Babu, T.P.This study focuses on energy performance investigation and environmental impact analysis of various new ecofriendly refrigerant blends as alternatives to high global warming potential refrigerant R22 theoretically. In this study, 23 refrigerants were considered at various composition. The present work considered the practical vapour compression refrigeration cycle for the performance assessment of various R22 alternatives. Essential studies such as toxicity, flammability, and total equivalent warming index of various novel refrigerants were also conducted in this study. Results obtained from practical vapour compression refrigeration cycle revealed that the energy efficiency ratio of refrigerants such as R1270 (2.860) and RB03 (R290/R152a of 60/40 in mass %) (2.854) was closer to the energy efficiency ratio of R22 (2.940). Volumetric refrigeration capacity (VRC) of R1270 (3293 kJ/m3) was similar to that of R22 (3297 kJ/m3) whereas VRC of RB03 (2908 kJ/m3) was almost similar to that of R407C (2925 kJ/m3) which was an alternative to R22. Compressor discharge temperature of RB03 was 15.78 ? lower when compared to R22. Flammability study revealed that all the new refrigerant blends (RB01 to RB04) were classified into weakly flammable (A2) and flammable (A3) category refrigerants whereas toxicity study revealed that all the investigated refrigerants were classified into non-toxic group (A). Refrigerant blend RB03 was less flammable compared to R1270. Total equivalent warming index analysis revealed that the environmental impact of R422A was 27.88% higher than R22 whereas RB03 has 4.97% lower environmental impact compared to R22. Overall, performance of refrigerant blend RB03 was better compared to 23 investigated refrigerants and it was very nearer to the performance of R22 and hence, it could be considered as an ecofriendly alternative to replace high global warming potential refrigerant R22 used in air conditioners. © IMechE 2020.
