    Analytical computation of gwp, odp, rf number and tewi analysis of various r134a/r1270/r290 blends as r22 alternatives
    (CRC Press/Balkema, 2018) Vali, S.S.; Ashok Babu, T.P.
    The principal objective of the present work is to compute the GWP, ODP, RF number and TEWI analysis of various ternary R134a/R1270/R290 blends as alternatives to R22. In this study thirteen refrigerant blends consists of R134a, R1270 and R290 at different compositions are taken. GWP and ODP of refrigerant blends are computed by using various simple correlations. The estimation of emission of greenhouse gases and flammability study of refrigerants are done by using TEWI and RF analysis respectively. Analytical results revealed that all the thirteen studied fluids are ozone friendly in nature. The GWP of refrigerant M6 (651) is lower than that of GWP of R22 (1760). RF analysis exhibited that all the thirteen refrigerant blends are categorized as ASHRAE A2 flammability category. Thermodynamic analysis revealed that COP of M6 (3.608) is higher that of COP of R22 (3.534). TEWI of M6 is lower among the R22 and thirteen studied fluids. Hence refrigerant M6 (R134a/R1270/R290 50/5/45 by mass%) is an alternative to R22. © 2018 Taylor & Francis Group, London.
  • Item
    Performance computation of window air conditioner with very low GWP near azeotropic refrigerant mixtures as a drop in Substitutes to R22
    (EDP Sciences edps@edpsciences.com, 2018) Vali, S.S.; Setty, T.P.; Babu, A.
    The principal objective of the present study is to compute the thermodynamic performance of window air conditioner based on standard vapour compression refrigeration cycle using R22, R407C and nineteen refrigerant mixtures. In this work nineteen R290/R1270 blends at different compositions are developed. A MATLAB code is developed to compute the thermodynamic performance parameters of all the studied refrigerants at condensing and evaporating temperatures of 54.4°C and 7.2°C respectively. The performance parameters are cooling effect, compressor work, COP, compressor discharge temperature, power per ton of refrigeration and volumetric cooling capacity respectively. Analytical results revealed that COP of new binary mixture R290/R1270 (90/10 by mass %) is 2.82% higher among R22, R407C and nineteen studied refrigerants. Energy required by the compressor per ton of refrigeration for R290/R1270 (90/10 by mass %) is 2.73% lower among R22, R407C and nineteen studied fluids. The discharge temperature of the compressor for all the nineteen investigated blends are reduced by 6.0-8.9oC compared to R22. Overall thermodynamic performance of window air conditioner with R290/R1270 (90/10 by mass %) is better than R22 with significant savings in energy consumption and hence it is an energy efficient ecofriendly refrigerant mixture as a drop in substitute to R22. © The Authors, published by EDP Sciences, 2018.