Faculty Publications
Permanent URI for this communityhttps://idr.nitk.ac.in/handle/123456789/18736
Publications by NITK Faculty
Browse
3 results
Search Results
Item A semi-automatic method for carotid artery wall segmentation in MR images(Institute of Electrical and Electronics Engineers Inc., 2017) Kumar, P.K.; Kesavadas, C.; Rajan, J.The quantification of carotid artery stenosis via imaging techniques guides the physicians to take a decision regarding surgical interventions. The measurement of wall thickness from magnetic resonance (MR) images is a promising approach to measure the degree of carotid stenosis. Manual tracing of the carotid vessel walls is time consuming and is sensitive to observer variability. Further, the existing segmentation techniques are limited by the poor contrast and presence of noise in MR images. The objective this paper is to present a novel segmentation strategy for carotid lumen and outer wall from MR images. The segmentation has been carried out in two stages which starts with a user assisted region of interest selection. In the first stage, an active contour based global segmentation has been applied to classify the lumen region. In the second stage, morphological gradient of the region of interest has been computed. This is followed by particle swarm optimization based localized segmentation to separate the wall region. The results demonstrate excellent correspondence between the automatic and manual tracings for lumen and outer walls of the carotid artery. © 2016 IEEE.Item State-of-the-art review on automated lumen and adventitial border delineation and its measurements in carotid ultrasound(Elsevier Ireland Ltd, 2018) Kumar, P.K.; Araki, T.; Rajan, J.; Laird, J.R.; Nicolaïdes, A.; Suri, J.S.Background and objective: Accurate, reliable, efficient, and precise measurements of the lumen geometry of the common carotid artery (CCA) are important for (a) managing the progression/regression of atherosclerotic build-up and (b) the risk of stroke. The image-based degree of stenosis in the carotid artery and the plaque burden can be predicted using the automated carotid lumen diameter (LD)/inter-adventitial diameter (IAD) measurements from B-mode ultrasound images. The objective of this review is to present the state-of-the-art methods and systems for the measurement of LD/IAD in CCA based on automated or semi-automated strategies. Further, the performance of these systems is compared based on various metrics for its measurements. Methods: The automated algorithms proposed for the segmentation of carotid lumen are broadly classified into two different categories as: region-based and boundary-based. These techniques are discussed in detail specifying their pros and cons. Further, we discuss the challenges encountered in the segmentation process along with its quantitative assessment. Lastly, we present stenosis quantification and risk stratification strategies. Results: Even though, we have found more boundary-based approaches compared to region-based approaches in the literature, however, the region-based strategy yield more satisfactory performance. Novel risk stratification strategies are presented. On a patient database containing 203 patients, 9 patients are identified as high risk patients, whereas 27 patients are identified as medium risk patients. Conclusions: We have presented different techniques for the lumen segmentation of the common carotid artery from B-mode ultrasound images and measurement of lumen diameter and inter-adventitial diameter. We believe that the issue regarding boundary-based techniques can be compensated by taking regional statistics embedded with boundary-based information. © 2018 Elsevier B.V.Item Accurate lumen diameter measurement in curved vessels in carotid ultrasound: an iterative scale-space and spatial transformation approach(Springer Verlag service@springer.de, 2017) Krishna Kumar, P.; Araki, T.; Rajan, J.; Saba, L.; Lavra, F.; Ikeda, N.; Sharma, A.M.; Shafique, S.; Nicolaïdes, A.; Laird, J.R.; Gupta, A.; Suri, J.S.Monitoring of cerebrovascular diseases via carotid ultrasound has started to become a routine. The measurement of image-based lumen diameter (LD) or inter-adventitial diameter (IAD) is a promising approach for quantification of the degree of stenosis. The manual measurements of LD/IAD are not reliable, subjective and slow. The curvature associated with the vessels along with non-uniformity in the plaque growth poses further challenges. This study uses a novel and generalized approach for automated LD and IAD measurement based on a combination of spatial transformation and scale-space. In this iterative procedure, the scale-space is first used to get the lumen axis which is then used with spatial image transformation paradigm to get a transformed image. The scale-space is then reapplied to retrieve the lumen region and boundary in the transformed framework. Then, inverse transformation is applied to display the results in original image framework. Two hundred and two patients’ left and right common carotid artery (404 carotid images) B-mode ultrasound images were retrospectively analyzed. The validation of our algorithm has done against the two manual expert tracings. The coefficient of correlation between the two manual tracings for LD was 0.98 (p < 0.0001) and 0.99 (p < 0.0001), respectively. The precision of merit between the manual expert tracings and the automated system was 97.7 and 98.7%, respectively. The experimental analysis demonstrated superior performance of the proposed method over conventional approaches. Several statistical tests demonstrated the stability and reliability of the automated system. © 2016, International Federation for Medical and Biological Engineering.
