Faculty Publications
Permanent URI for this communityhttps://idr.nitk.ac.in/handle/123456789/18736
Publications by NITK Faculty
Browse
5 results
Search Results
Item A new non-local maximum likelihood estimation method for Rician noise reduction in magnetic resonance images using the Kolmogorov-Smirnov test(Elsevier, 2014) Rajan, J.; den Dekker, A.J.; Sijbers, J.Denoising algorithms play an important role in the enhancement of magnetic resonance (MR) images. Effective denoising is vital for proper analysis and accurate quantitative measurements from MR images. Maximum Likelihood (ML) estimation methods were proved to be very effective in denoising MR images. Among the ML based methods, the recently proposed non-local maximum likelihood (NLML) approach gained much attention. In the NLML method, the samples for the ML estimation of the true underlying intensity are selected in a non-local way based on the intensity similarity of the pixel neighborhoods. This similarity is generally measured using the Euclidean distance. A drawback of this approach is the usage of a fixed sample size for the ML estimation resulting in over- or under-smoothing. In this work, we propose an NLML estimation method for denoising MR images in which the samples are selected in an adaptive and statistically supported way using the Kolmogorov-Smirnov (KS) similarity test. The method has been tested both on simulated and real data, showing its effectiveness. © 2013 Elsevier B.V.Item Two Automated Techniques for Carotid Lumen Diameter Measurement: Regional versus Boundary Approaches(Springer New York LLC barbara.b.bertram@gsk.com, 2016) Araki, T.; Kumar, P.K.; Suri, H.S.; Ikeda, N.; Gupta, A.; Saba, L.; Rajan, J.; Lavra, F.; Sharma, A.M.; Shafique, S.; Nicolaïdes, A.; Laird, J.R.; Suri, J.S.The degree of stenosis in the carotid artery can be predicted using automated carotid lumen diameter (LD) measured from B-mode ultrasound images. Systolic velocity-based methods for measurement of LD are subjective. With the advancement of high resolution imaging, image-based methods have started to emerge. However, they require robust image analysis for accurate LD measurement. This paper presents two different algorithms for automated segmentation of the lumen borders in carotid ultrasound images. Both algorithms are modeled as a two stage process. Stage one consists of a global-based model using scale-space framework for the extraction of the region of interest. This stage is common to both algorithms. Stage two is modeled using a local-based strategy that extracts the lumen interfaces. At this stage, the algorithm-1 is modeled as a region-based strategy using a classification framework, whereas the algorithm-2 is modeled as a boundary-based approach that uses the level set framework. Two sets of databases (DB), Japan DB (JDB) (202 patients, 404 images) and Hong Kong DB (HKDB) (50 patients, 300 images) were used in this study. Two trained neuroradiologists performed manual LD tracings. The mean automated LD measured was 6.35 ± 0.95 mm for JDB and 6.20 ± 1.35 mm for HKDB. The precision-of-merit was: 97.4 % and 98.0 % w.r.t to two manual tracings for JDB and 99.7 % and 97.9 % w.r.t to two manual tracings for HKDB. Statistical tests such as ANOVA, Chi-Squared, T-test, and Mann-Whitney test were conducted to show the stability and reliability of the automated techniques. © 2016, Springer Science+Business Media New York.Item GPU implementation of non-local maximum likelihood estimation method for denoising magnetic resonance images(Springer Verlag service@springer.de, 2017) Upadhya, A.H.K.; Talawar, B.; Rajan, J.Magnetic resonance imaging (MRI) is a widely deployed medical imaging technique used for various applications such as neuroimaging, cardiovascular imaging and musculoskeletal imaging. However, MR images degrade in quality due to noise. The magnitude MRI data in the presence of noise generally follows a Rician distribution if acquired with single-coil systems. Several methods are proposed in the literature for denoising MR images corrupted with Rician noise. Amongst the methods proposed in literature for denoising MR images corrupted with Rician noise, the non-local maximum likelihood methods (NLML) and its variants are popular. In spite of the performance and denoising quality, NLML algorithm suffers from a tremendous time complexity O(m3N3) , where m3 and N3 represent the search window and image size, respectively, for a 3D image. This makes the algorithm challenging for deployment in the real-time applications where fast and prompt results are required. A viable solution to this shortcoming would be the application of a data parallel processing framework such as Nvidia CUDA so as to utilize the mutually exclusive and computationally intensive calculations to our advantage. The GPU-based implementation of NLML-based image denoising achieves significant speedup compared to the serial implementation. This research paper describes the first successful attempt to implement a GPU-accelerated version of the NLML algorithm. The main focus of the research was on the parallelization and acceleration of one computationally intensive section of the algorithm so as to demonstrate the execution time improvement through the application of parallel processing concepts on a GPU. Our results suggest the possibility of practical deployment of NLML and its variants for MRI denoising. © 2016, Springer-Verlag Berlin Heidelberg.Item Recent Advancements in Retinal Vessel Segmentation(Springer New York LLC barbara.b.bertram@gsk.com, 2017) Srinidhi, C.L.; Aparna., P.; Rajan, J.Retinal vessel segmentation is a key step towards the accurate visualization, diagnosis, early treatment and surgery planning of ocular diseases. For the last two decades, a tremendous amount of research has been dedicated in developing automated methods for segmentation of blood vessels from retinal fundus images. Despite the fact, segmentation of retinal vessels still remains a challenging task due to the presence of abnormalities, varying size and shape of the vessels, non-uniform illumination and anatomical variability between subjects. In this paper, we carry out a systematic review of the most recent advancements in retinal vessel segmentation methods published in last five years. The objectives of this study are as follows: first, we discuss the most crucial preprocessing steps that are involved in accurate segmentation of vessels. Second, we review most recent state-of-the-art retinal vessel segmentation techniques which are classified into different categories based on their main principle. Third, we quantitatively analyse these methods in terms of its sensitivity, specificity, accuracy, area under the curve and discuss newly introduced performance metrics in current literature. Fourth, we discuss the advantages and limitations of the existing segmentation techniques. Finally, we provide an insight into active problems and possible future directions towards building successful computer-aided diagnostic system. © 2017, Springer Science+Business Media New York.Item A benchmark study of automated intra-retinal cyst segmentation algorithms using optical coherence tomography B-scans(Elsevier Ireland Ltd, 2018) Girish, G.N.; Anima, V.A.; Kothari, A.R.; Sudeep, P.V.; Roychowdhury, S.; Rajan, J.(Background and objectives) Retinal cysts are formed by accumulation of fluid in the retina caused by leakages from inflammation or vitreous fractures. Analysis of the retinal cystic spaces holds significance in detection and treatment of several ocular diseases like age-related macular degeneration, diabetic macular edema etc. Thus, segmentation of intra-retinal cysts and quantification of cystic spaces are vital for retinal pathology and severity detection. In the recent years, automated segmentation of intra-retinal cysts using optical coherence tomography B-scans has gained significant importance in the field of retinal image analysis. The objective of this paper is to compare different intra-retinal cyst segmentation algorithms for comparative analysis and benchmarking purposes. (Methods) In this work, we employ a modular approach for standardizing the different segmentation algorithms. Further, we analyze the variations in automated cyst segmentation performances and method scalability across image acquisition systems by using the publicly available cyst segmentation challenge dataset (OPTIMA cyst segmentation challenge). (Results) Several key automated methods are comparatively analyzed using quantitative and qualitative experiments. Our analysis demonstrates the significance of variations in signal-to-noise ratio (SNR), retinal layer morphology and post-processing steps on the automated cyst segmentation processes. (Conclusion) This benchmarking study provides insights towards the scalability of automated processes across vendor-specific imaging modalities to provide guidance for retinal pathology diagnostics and treatment processes. © 2017 Elsevier B.V.
