Faculty Publications
Permanent URI for this communityhttps://idr.nitk.ac.in/handle/123456789/18736
Publications by NITK Faculty
Browse
7 results
Search Results
Item Fuzzy logic approach for reactive power coordination in grid connected wind farms to improve steady state voltage stability(Institution of Engineering and Technology journals@theiet.org, 2017) Moger, T.; Dhadbanjan, T.This study presents a fuzzy logic approach for reactive power coordination in grid connected wind farms with different types of wind generator units to improve steady state voltage stability of power systems. The load bus voltage deviation is minimised by changing the reactive power controllers according to their sensitivity using fuzzy set theory. The proposed approach uses only few controllers of high sensitivity to achieve the desired objectives. The 297-bus and 417-bus equivalent grid connected wind systems are considered to present the simulation results. To prove the effectiveness of the proposed approach, a comparative analysis is carried out with the conventional linear programming based reactive power optimisation technique. Results demonstrated that the proposed approach is more effective in improving the system performance as compared with the conventional existing technique. © 2016 The Institution of Engineering and Technology.Item Impact of Different PQ Models of Wind Turbine Generating Units (WTGUs) on System Voltage Performance(Walter de Gruyter GmbH info@degruyter.com, 2017) Moger, T.; Dhadbanjan, T.This paper presents the voltage performance analysis of the system with various types of wind turbine generating units (WTGUs). A detailed voltage performance analysis is carried out by considering the different PQ models used for computing the reactive power output of the WTGUs (fixed/semi-variable speed and variable speed WTGUs). The different PQ models of fixed/semi-variable speed WTGUs incorporated for the studies are voltage dependent model, voltage independent model, power factor based model, and PX model. In addition, the variable speed WTGUs are also considered in different fixed power factor mode of operation. Based on these models, a comparative analysis is presented. A modified 27-bus equivalent distribution test system with dispersed wind generation is considered for the studies. Further, the case studies have been carried out by considering the various wind power output levels of WTGUs to examine its impact on system voltage performance. From the comparative analysis, the power factor based model can be the best choice over the other models (which are based on voltages) for the system studies with fixed/semi-variable speed WTGUs. © 2017 Walter de Gruyter GmbH, Berlin/Boston 2017.Item Comprehensive review on low voltage ride through capability of wind turbine generators(John Wiley and Sons Ltd cs-journals@wiley.co.uk, 2020) Hiremath, R.; Moger, T.Wind energy has made more inroads in renewable power generation due to environmental impact of conventional energy sources. The high penetration of grid connected wind energy has emerged as a recent trend in many countries. On the other hand, the problem of power generation loss due to the grid fault also arisen. The recent technological advancement suggests the importance of low voltage ride through (LVRT) in wind energy conversion system (WECS). However, LVRT is a technique in making uninterrupted connectivity of WECS in the presence of grid fault. This paper presents the state of the art of LVRT capabilities of various wind turbine generators using FACTS devices and different converter controllers. Also, the main challenging issues and different approaching strategies in LVRT are addressed. Finally, extracting all important features from distinct papers, new dimension of LVRT is presented for the power quality and power generation loss problems. © 2020 John Wiley & Sons LtdItem Modified Super Twisting algorithm based sliding mode control for LVRT enhancement of DFIG driven wind system(Elsevier Ltd, 2022) Hiremath, R.; Moger, T.The grid-connected Doubly Fed Induction Generator (DFIG) system is exposed to severe grid faults. The DFIG is sensitive to grid disturbances, which lead to consideration in the controller design. This paper proposed the Modified Super Twisting (MST) algorithm for the Low Voltage Ride Through (LVRT) enhancement under voltage sag condition. This proposed algorithm is implemented using the 2nd Order Sliding Mode (SOSM) to control the DFIG based wind generator. The higher-order switching functions are introduced in the SOSM for sliding surface control. Moreover, the Lyapunov analysis for the MST algorithm brings down the chattering amplitude. The advantages of the proposed algorithm are that it reduces the system uncertainties, chattering effect and improves the settling period of the system parameters. The performance of the proposed algorithm is compared with existing algorithms in the literature with the help of MATLAB/SIMULINK. The Hardware-In-Loop (HIL) is used to validate the simulation results, which have been performed on the OPAL-RT setup. In addition, the proposed algorithm is also tested on an equivalent model of the practical Wind Farm (WF). Based on the studies, it is found that the proposed algorithm enhanced the LVRT performance of the single Wind Turbine (WT)-DFIG system as well as the practical WF under transient conditions. © 2022 The AuthorsItem Probabilistic Load Flow for Wind Integrated Power System Considering Node Power Uncertainties and Random Branch Outages(Institute of Electrical and Electronics Engineers Inc., 2023) Singh, V.; Moger, T.; Jena, D.This paper proposes an analytical probabilistic load flow (PLF) approach that considers conventional generator outages, load variability, and random branch outages. The branch outages are modeled as 0-1 distributions of fictitious power injections at the appropriate nodes. The distribution of state variables and line power flows is then obtained using a combined Cumulant and Gram-Charlier series expansion approach. The proposed PLF performs contingency sequencing with fuzzy logic to eliminate random line checking and avoid masking mistakes faced by performance index-based algorithms. The Jacobian inverse calculation in the traditional Cumulant method is eliminated to conserve storage space and speed up the computation using the Gauss-Jordan method. The correlations among loads and wind power generations has been modeled using the Nataf transformation process. Results of 24-bus and 259-bus equivalent systems of the Indian southern and western power grids are analyzed and validated with those obtained using the Monte Carlo simulation method. The suggested method's efficacy is justified by its accuracy and low computational burden. © 2010-2012 IEEE.Item Probabilistic Load Flow Approach Combining Cumulant Method and K-Means Clustering to Handle Large Fluctuations of Stochastic Variables(Institute of Electrical and Electronics Engineers Inc., 2023) Singh, V.; Moger, T.; Jena, D.The modern electrical power system faces various uncertainties, including load fluctuations, forced outages of conventional generators, network branches. Furthermore, the rising penetration of wind power generation introduces additional uncertainty, causing difficulties in power system planning, operation. This paper uses an analytical probabilistic load flow approach to account for all such uncertainties. The random branch outages are simulated using the fictional powers injections into the relevant nodes. A fuzzy method is used to perform contingency sequencing to avoid masking mistakes that might occur when utilizing performance index-based sequencing methods. The sparse Jacobian inverse is eliminated to preserve storage space, accelerate the computation. A modified Cumulant method is used in conjunction with the K-means clustering process to deal with the substantial fluctuations of the input variables. In the proposed approach, the correlated samples are generated using inverse Nataf transformation. These correlated samples are clustered using K-means clustering. The Cumulant method is applied within each cluster, total probability law is used to integrate each cluster's findings. The proposed PLF is tested on 24-bus, 259-bus wind integrated equivalent systems. Compared with the Monte-Carlo simulation, the proposed PLF yields computationally efficient, more accurate findings. © 1972-2012 IEEE.Item Maximum entropy based probabilistic load flow for assessing input uncertainties and line outages in wind-integrated power systems(Elsevier Ltd, 2025) Singh, V.; Moger, T.; Jena, D.The swift expansion of distributed generation, particularly from photovoltaics and wind turbines, poses a formidable challenge to conventional probabilistic load flow (PLF) methods. This paper addresses the urgent need for a robust and efficient PLF approach by investigating a maximum entropy (ME) based probabilistic density function (PDF) approximation, utilizing advanced cumulant arithmetic from linearized power flow formulation. The ME-PLF method notably enhances the accuracy of output PDFs under extensive uncertainties, such as load demand fluctuations and disturbances in network branches. Unlike the Gram–Charlier expansion (GCE) reconstruction method, ME-PLF effectively eliminates the issue of erroneously obtaining negative values in the tail regions of the PDFs. Additionally, the fundamental cumulant method (CM) is refined to better model dependencies between wind power generators (WPGs) and loads. The simulations are conducted using the MATLAB programming software. Results from practical test systems have been validated against those obtained using the Monte Carlo simulation method. The suggested method has been proven to be highly effective due to its preciseness and reduced computational effort. © 2025 Elsevier B.V.
