Faculty Publications
Permanent URI for this communityhttps://idr.nitk.ac.in/handle/123456789/18736
Publications by NITK Faculty
Browse
5 results
Search Results
Item Performance evaluation of partially filled high porosity metal foam configurations in a pipe(Elsevier Ltd, 2021) Jadhav, P.H.; Gnanasekaran, N.; Arumuga Perumal, D.A.; Mobedi, M.In this contemporary research, a parametric analysis of partially filled high porosity metallic foams in a horizontal conduit is performed to augment heat transfer with reasonable pressure drop. The investigation includes six different models filled partly with aluminium foam by varying internal diameter of foams from the wall side and external diameter of foam from the core of the tube. The pore density of the foam ranges from 10 to 45 PPI and their porosity varies from 0.90 to 0.95. Flow dynamics are captured using Darcy Extended Forchheimer model for the porous filled region and two-equation turbulence k-? model employed in clear region of the fluid. The local thermal non-equilibrium assumption is incorporated in porous filled region of the conduit to compute the heat transport characteristics. The results showed that the thermal performance factor of 10 PPI aluminium foam performs close to the 10 PPI expensive copper foam. The performance factor is found to be higher for 30 PPI aluminium foam amongst the PPI's of the foam considered. However, the performance factor is found to be 2.93, 2.22 and 1.73 for 30PPI, 45 PPI and 20PPI with their porosities of 0.92, 0.90 and 0.90, respectively for the model 1, model 2 and model 3 at lower Reynolds number of 4500 and then it decreases progressively with increasing flow rates of the fluid. The results of average wall temperature, average Nusselt number and Colburn j factor are also evaluated to obtain best possible performance. © 2021Item Various trade-off scenarios in thermo-hydrodynamic performance of metal foams due to variations in their thickness and structural conditions(MDPI, 2021) Trilok, G.; Gnanasekaran, N.; Mobedi, M.The long standing issue of increased heat transfer, always accompanied by increased pressure drop using metal foams, is addressed in the present work. Heat transfer and pressure drop, both of various magnitudes, can be observed in respect to various flow and heat transfer influencing aspects of considered metal foams. In this regard, for the first time, orderly varying pore density (characterized by visible pores per inch, i.e., PPI) and porosity (characterized by ratio of void volume to total volume) along with varied thickness are considered to comprehensively analyze variation in the trade-off scenario between flow resistance minimization and heat transfer augmentation behavior of metal foams with the help of numerical simulations and TOPSIS (Technique for Order of Preference by Similarity to Ideal Solution) which is a multi-criteria decision-making tool to address the considered multi-objective problem. A numerical domain of vertical channel is modelled with zone of metal foam porous media at the channel center by invoking LTNE and Darcy–Forchheimer models. Metal foams of four thickness ratios are considered (1, 0.75, 0.5 and 0.25), along with varied pore density (5, 10, 15, 20 and 25 PPI), each at various porosity conditions of 0.8, 0.85, 0.9 and 0.95 porosity. Numerically obtained pressure and temperature field data are critically analyzed for various trade-off scenarios exhibited under the abovementioned variable conditions. A type of metal foam based on its morphological (pore density and porosity) and configurational (thickness) aspects, which can participate in a desired trade-off scenario between flow resistance and heat transfer, is illustrated. © 2021 by the authors. Licensee MDPI, Basel, Switzerland.Item Correlations and Numerical Modeling of Stacked Woven Wire-Mesh Porous Media for Heat Exchange Applications(MDPI, 2022) Trilok, G.; Srinivas, K.E.S.; Harikrishnan, D.; Gnanasekaran, N.; Mobedi, M.Metal foams have gained attention due to their heat transfer augmenting capabilities. In the literature, correlations describing relations among their morphological characteristics have successfully been established and well discussed. However, collective expressions that categorize stacked wire mesh based on their morphology and thermo-hydraulic expressions required for numerical modeling are less explored in the literature. In the present study, cross relations among the morphological characteristics of stacked wire-mesh were arrived at based on mesh-size, wire diameter and stacking type, which are essential for describing the medium and determining key input parameters required for numerical modeling. Furthermore, correlation for specific surface area, a vital parameter that plays a major role in interstitial heat transfer, is provided. With the arrived correlations, properties of stacked wire-mesh samples of orderly varied mesh-size and porosity are obtained for various stacking scenarios, and corresponding thermo-hydraulic parameters appearing in the governing equations are evaluated. A vertical channel housing the categorized wire-mesh porous media is numerically modeled to analyze thermal and flow characteristics of such a medium. The proposed correlations can be used in confidence to evaluate thermo-hydraulic parameters appearing in governing equations in order to numerically model various samples of stacked wire-mesh types of porous media in a variety of heat transfer applications. © 2022 by the authors. Licensee MDPI, Basel, Switzerland.Item Analysis of functionally graded metal foams for the accomplishment of heat transfer enhancement under partially filled condition in a heat exchanger(Elsevier Ltd, 2023) Jadhav, P.H.; Gnanasekaran, N.; Mobedi, M.The use of partially filled high porosity graded aluminum and copper foams is explored to satisfy both heat transfer and pressure drop in a heat exchanger. Both positive and negative orientations are accomplished for the enhancement of heat transfer with reduction in the pressure drop. The present research includes three different configurations M1, M2 and M3 (porous layer inner diameter = 0.06 m, 0.04 m, and 0.02 m, respectively, while outer diameter = 0.10 m) partially filled with positive (i.e., increasing, 20/45 PPI) negative (i.e., decreasing, 45/20 PPI) and compound (i.e., 45 Cu/20 Al PPI) graded porous layer thickness. Each configuration involves three different graded porous layer to present the optimum graded porous layer thickness. The thermo-hydrodynamic characteristics are apprehended by using Darcy Extended Forchheimer (DEF) flow and local thermal non-equilibrium (LTNE) models for the partially filled graded porous structure and k-ω turbulence model is accomplished in open passage flow of the conduit. The decreasing graded foam located inside the models M1 and M2 performed 1.68%–12.85% and 13.42%–23.32% higher heat transfer rate compared to without graded metal foam of models M2 and M3, respectively accompanied with 55.43%–84.02% and 35.69%–50.31% lesser pumping power. © 2022 Elsevier LtdItem Reconciliation of wire woven mesh porous media in controlling the desired heat transfer and pressure drop(Emerald Publishing, 2025) Trilok, T.; Gnanasekaran, N.; Mobedi, M.Purpose: Despite the reputation of the metal-based porous media for their ability to augment heat transfer as widely witnessed in the literature and practically operating heat exchanging applications, the coexisting penalty of the increased pressure drop demanding increased pumping power poses a major concern that invites the need for an alternate solution to handle this unsought outcome. Therefore, this study aims at providing a better solution to the existing cost and benefit scenarios to benefit a plethora of engineering applications including energy transfer, energy storage and energy conversion. Design/methodology/approach: This work highlights on the property of stacked woven wire mesh porous media such as their stacking types, porous conditions and thickness scenarios that can potentially result in distinct trade-off scenarios. A vertical channel is numerical modelled by using REV scaled modelling technique using Darcy-Forchheimer and local thermal non-equilibrium models to illustrate the possibilities of this variety of trade off scenarios between the desirable heat transfer and the unsought flow resistance. Findings: This work illustrates the advantages of wire mesh-based porous medium and its distinct potential in controlling the existing trade-offs between the cost and benefit aspects. It is found that by varying the features of wire mesh porous media, the interplay between the conflictingly existing characteristics can be much easily handled specific to distinct requirements associated with variety of engineering applications. Originality/value: The study emphasizes on a new solution or methodology to handle the penalty of pressure drop associated with metal-based porous media. Through this study, a novel approach to control the ultimately costing pumping power at the benefit of increased heat transfer is provided considering various requirements that could be associated with any thermal management systems. Various possibilities and potentials of wire mesh porous media are illustrated highlighting on their benefit of ease with which the mentioned goals can be achieved. © 2024, Emerald Publishing Limited.
