Faculty Publications
Permanent URI for this communityhttps://idr.nitk.ac.in/handle/123456789/18736
Publications by NITK Faculty
Browse
4 results
Search Results
Item Exergy Analysis of a Triangular Duct Solar Air Heater with Square Ribs(Springer Science and Business Media Deutschland GmbH, 2022) Nidhul, K.; Kumar, S.; Yadav, A.K.; Anish, S.The awareness about limited energy resources has urged the scientific community to scrutinize the energy conversion devices and optimize existing limited resources. In this analytical study, the exergetic performance analysis of a triangular cross-section square ribbed solar air heater (SAH) is compared with a conventional SAH. Reynolds number (Re) and temperature rise parameter (∆T/G) are varied, and their effect on exergetic efficiency is quantified. For the present study, maximum exergetic efficiency for the present study is obtained for non-dimensionalized rib height (e/D) of 0.05 and non-dimensionalized rib pitch (P/e) of 10. The optimum combinations of roughness parameters are interpreted through plots to design turbulators for triangular cross-section solar air heaters. © 2022, The Author(s), under exclusive license to Springer Nature Singapore Pte Ltd.Item Critical review of ribbed solar air heater and performance evaluation of various V-rib configuration(Elsevier Ltd, 2021) Nidhul, K.; Yadav, A.K.; Anish, S.; Kumar, S.The low heat transfer rate in a flat plate solar air heater (SAH) is due to the development of a laminar sub-layer near the heated absorber plate. Owing to this, the plate temperature rises substantially, instigating losses and thus reducing the efficiency. Extensive research has been carried out to mitigate this problem, of which passive technique emerged to be a promising solution. The passive method involves the application of fins/turbulators/ribs on the surface where the boundary layer develops so that it breaks the same. Various profiles and configurations of the ribs ranging from transverse to inclined and continuous to discrete have been presented concisely. Correlations on Nusselt number (Nu) and friction factor (f) for different rib configurations have been summarized in order so that it can be accessed for future research. 3-D CFD analysis is carried out to gain insight into the flow pattern of various V-ribbed SAH, and with the help of streamlines and contours, the findings are established. Furthermore, various exergy destruction has been studied in detail for different V-rib configurations, namely– V-rib, multiple V-rib, and multiple V-rib with the gap, and analyzed in detail for prospective studies. Exergetic performance study of these rib configurations indicates that the multiple ribs and the multiple rib-gap combinations enhance exergetic efficiency (ηex) by 12% and 31.6%, respectively, in comparison to V-rib SAH. © 2021 Elsevier LtdItem Enhanced thermo-hydraulic performance in a V-ribbed triangular duct solar air heater: CFD and exergy analysis(Elsevier Ltd, 2020) Nidhul, K.; Kumar, S.; Yadav, A.; Anish, S.Computational fluid dynamics (CFD) and exergy analysis are conducted to investigate the impact of secondary flow produced by V-ribs on the overall performance of a triangular solar air heater (SAH) duct. For a fixed relative rib pitch (Rp = 10) and relative rib height (Rh = 0.05), the effect of rib inclination (?) is studied using CFD technique for varying Reynolds number (5000 ? Re ? 20000). Based on the CFD simulation results, empirical correlations capable of predicting Nu and f with an absolute variance of 8.7%, and 4.7%, respectively, are developed. Employing these correlations, exergetic performance analysis is carried out. Maximum effectiveness parameter (?) of 2.01 is obtained for ? = 45° at Re = 7500. The exergy analysis reveals that the entropy generated is lower for the ribbed triangular duct compared to the smooth duct with maximum enhancement in exergetic efficiency (?ex) as 23% for ? = 45°. The study is extended for the rectangular duct to compare the performance with the ribbed triangular duct SAH (? = 45°). Results show that ribbed triangular duct SAH (? = 45°) is superior over various configurations of the ribbed rectangular duct SAH at higher mass flow rates. © 2020 Elsevier LtdItem Influence of Rectangular Ribs on Exergetic Performance in a Triangular Duct Solar Air Heater(American Society of Mechanical Engineers (ASME), 2020) Nidhul, K.; Kumar, S.; Yadav, A.; Anish, S.Several artificial roughness (ribs) configurations have been used in flat plate solar air heaters (SAH) in recent years to improve their overall performance. In the present work, energy and exergy analyses of rectangular ribs in a triangular duct SAH for varying relative rib heights (e/D = 0.02-0.04), relative rib pitches (P/e = 5-15), and rib aspect ratios (e/w = 0.5-4) are evaluated and compared with smooth SAH. The analysis reveals that the entropy generated due to heat transfer is lower for the ribbed triangular duct compared to the smooth duct. It is also observed that the width of the rib plays a crucial role in minimizing heat losses to the environment. A maximum reduction of 43% and 62% in exergy losses to the environment and exergy losses due to heat transfer to the fluid is achieved, respectively, with a rib aspect ratio (e/w) of 4 compared to the smooth plate. It is found that in contrast to the smooth plate, ribs beneath the absorber plate effectively improves thermal and exergetic efficiency. Maximum enhancement of 36% and 17% is obtained in exergetic efficiency (?ex) and thermal efficiency (th), respectively, for e/w = 4, P/e = 10 and e/D = 0.04. Results also show the superiority of the ribbed triangular duct over the ribbed rectangular duct for an application requiring compact SAH with a higher flowrate. © 2020 by ASME.
