Faculty Publications

Permanent URI for this communityhttps://idr.nitk.ac.in/handle/123456789/18736

Publications by NITK Faculty

Browse

Search Results

Now showing 1 - 2 of 2
  • Item
    Performance analysis of valveless micropump with disposable chamber actuated through Amplified Piezo Actuator (APA) for biomedical application
    (Elsevier Ltd, 2020) Mohith, M.; Karanth P, N.; Kulkarni, S.M.
    The precise manipulation of fluid through pumping systems has been the technological challenge in microfluidic applications. The biomedical applications call for precise and accurate delivery of fluid through miniaturized pumping systems. This paper presents a novel valveless micropump for biomedical applications operated by the Amplified Piezo Actuator. Integrating the disposable chamber and reusable actuator with the proposed micropump allows the actuator to be reused and eliminates the possibility of infection or contagion. The micropump was fabricated using low-cost polymeric materials like Polymethylmethacrylate (PMMA), Silicone rubber through CNC milling, Laser Cutting, conventional moulding operation. The micropump chamber, nozzle/diffusers, and a bossed diaphragm constituted disposable part and Amplified Piezo Actuator with structural support formed the reusable part of the micropump. The bossed diaphragm of the pump chamber consists of a central cylindrical protrusion to reduce the force of adhesion on the diaphragm and transmit force required for micropump actuation. A theoretical analysis was performed to assess the effect of diaphragm thickness and the bossed region on the effective stiffness of the diaphragm, which in turn influences the deflection achieved. Besides, an analytical approach has been presented to address the effect of adhesive force on the diaphragm surface due to the residual fluid and chamber depth. The experimental characterization of the micropump was carried out to determine the optimal performance parameters with water, fluids mimicking blood plasma, and whole blood. Based on the experimental results, the pumping rate and head developed by the micropump have been significantly affected by factors such as bossed ratio, diaphragm thickness, depth of the micropump chamber, and viscosity of the fluid. The optimum configuration of the micropump cosidered silicone rubber diaphragm with thickness of 0.20 mm having a bossed ratio of 0.33 and a chamber depth of 1.25 mm. With the optimal operating parameters of 150 V sinusoidal input of frequency 5 Hz, the proposed micropump was capable of delivering 7.192 ml/min, 6.108 ml/min, and 5.013 ml/min of water and blood plasma, whole blood mimicking fluid with the maximum backpressure of 294.00 Pa, 226.243 Pa, and 204.048 Pa respectively. The corresponding resolution, i.e., pumping volume/stroke of the micropump was about 23.972 µl, 20.358 µl, and 16.708 µl, respectively. © 2020 Elsevier Ltd
  • Item
    Performance comparison of piezo actuated valveless micropump with central excitation and annular excitation for biomedical applications
    (IOP Publishing Ltd, 2021) Mohith, S.; Karanth P, N.; Kulkarni, S.M.; Desai, V.; Patil, S.S.
    In recent years, microfluidic devices, particularly micropumps, are extensively utilized in biomedical applications. The micropump used in biomedical applications needs to possess precise delivery of fluids at requires rate and pressure. The present work proposes a valveless mechanical micropump with a disposable chamber integrated with a novel concept of annular excitation of the diaphragm to fulfil the need for precise delivery of fluids in biomedical applications. The proposed design of the micropump involves a reusable configuration of the amplified piezoelectric actuator (APA) for micropump actuation and a disposable pump chamber. The pumping of the fluids occurs through the oscillation of the silicone rubber bossed diaphragm. The performance of a mechanical micropump depends on the oscillation amplitude of the diaphragm. Thus, the conventional approach of central excitation of the bossed diaphragm is replaced by a novel approach of annular excitation intended to enhance the deflection range, thus the volumetric performance of the micropump. An experimental comparative study is carried out to assess the deflection characteristics of central excitation and annular excitation of the bossed diaphragm. The maximum deflection measured with the annularly excited configuration of the bossed diaphragm is about 1953.4 ± 8.00 µm at 150 V, 43.5 Hz, which is superior to the maximum deflection of centrally excited configuration delivering 717.99 ± 4.00 µm at 150 V, 9.5 Hz. Further, the experimental studies aimed to fabricate and characterize the micropump with central and annular excitation approaches. The proposed micropump with central excitation delivered the maximum water flow rate of about 7.192 ± 0.147 ml min-1 and backpressure of 0.294 kPa at 150 V, 5 Hz. However, the enhancement of the deflection characteristics of the bossed diaphragm under annular excitation leads to performance enhancement of the micropump with the flow rate of 95.10 ± 0.444 ml min-1 and backpressure of 1.472 kPa at 150, 30 Hz. © 2021 IOP Publishing Ltd.