Faculty Publications
Permanent URI for this communityhttps://idr.nitk.ac.in/handle/123456789/18736
Publications by NITK Faculty
Browse
3 results
Search Results
Item Carotid inter-adventitial diameter is more strongly related to plaque score than lumen diameter: An automated tool for stroke analysis(John Wiley and Sons Inc. P.O.Box 18667 Newark NJ 07191-8667, 2016) Saba, L.; Araki, T.; Krishna Kumar, P.; Rajan, J.; Lavra, F.; Ikeda, N.; Sharma, A.M.; Shafique, S.; Nicolaïdes, A.; Laird, J.R.; Gupta, A.; Suri, J.S.Purpose: To compare the strength of correlation between automatically measured carotid lumen diameter (LD) and interadventitial diameter (IAD) with plaque score (PS). Methods: Retrospective study on a database of 404 common carotid artery B-mode sonographic images from 202 diabetic patients. LD and IAD were computed automatically using an advanced computerized edge detection method and compared with two distinct manual measurements. PS was computed by adding the maximal thickness in millimeters of plaques in segments taken from the internal carotid artery, bulb, and common carotid artery on both sides. Results: The coefficient of correlation was 0.19 (p < 0.007) between LD and PS, and 0.25 (p < 0.0006) between IAD and PS. After excluding 10 outliers, coefficient of correlation was 0.25 (p < 0.0001) between LD and PS, and 0.38 (p < 0.0001) between IAD and PS. The precision of merit of automated versus the two manual measurements was 96.6% and 97.2% for LD, and 97.7% and 98.1%, for IAD, respectively. Conclusions: Our automated measurement system gave satisfying results in comparison with manual measurements. Carotid IAD was more strongly correlated to PS than carotid LD in this population sample of Japanese diabetic patients. © 2016 Wiley Periodicals, Inc.Item Two Automated Techniques for Carotid Lumen Diameter Measurement: Regional versus Boundary Approaches(Springer New York LLC barbara.b.bertram@gsk.com, 2016) Araki, T.; Kumar, P.K.; Suri, H.S.; Ikeda, N.; Gupta, A.; Saba, L.; Rajan, J.; Lavra, F.; Sharma, A.M.; Shafique, S.; Nicolaïdes, A.; Laird, J.R.; Suri, J.S.The degree of stenosis in the carotid artery can be predicted using automated carotid lumen diameter (LD) measured from B-mode ultrasound images. Systolic velocity-based methods for measurement of LD are subjective. With the advancement of high resolution imaging, image-based methods have started to emerge. However, they require robust image analysis for accurate LD measurement. This paper presents two different algorithms for automated segmentation of the lumen borders in carotid ultrasound images. Both algorithms are modeled as a two stage process. Stage one consists of a global-based model using scale-space framework for the extraction of the region of interest. This stage is common to both algorithms. Stage two is modeled using a local-based strategy that extracts the lumen interfaces. At this stage, the algorithm-1 is modeled as a region-based strategy using a classification framework, whereas the algorithm-2 is modeled as a boundary-based approach that uses the level set framework. Two sets of databases (DB), Japan DB (JDB) (202 patients, 404 images) and Hong Kong DB (HKDB) (50 patients, 300 images) were used in this study. Two trained neuroradiologists performed manual LD tracings. The mean automated LD measured was 6.35 ± 0.95 mm for JDB and 6.20 ± 1.35 mm for HKDB. The precision-of-merit was: 97.4 % and 98.0 % w.r.t to two manual tracings for JDB and 99.7 % and 97.9 % w.r.t to two manual tracings for HKDB. Statistical tests such as ANOVA, Chi-Squared, T-test, and Mann-Whitney test were conducted to show the stability and reliability of the automated techniques. © 2016, Springer Science+Business Media New York.Item Accurate lumen diameter measurement in curved vessels in carotid ultrasound: an iterative scale-space and spatial transformation approach(Springer Verlag service@springer.de, 2017) Krishna Kumar, P.; Araki, T.; Rajan, J.; Saba, L.; Lavra, F.; Ikeda, N.; Sharma, A.M.; Shafique, S.; Nicolaïdes, A.; Laird, J.R.; Gupta, A.; Suri, J.S.Monitoring of cerebrovascular diseases via carotid ultrasound has started to become a routine. The measurement of image-based lumen diameter (LD) or inter-adventitial diameter (IAD) is a promising approach for quantification of the degree of stenosis. The manual measurements of LD/IAD are not reliable, subjective and slow. The curvature associated with the vessels along with non-uniformity in the plaque growth poses further challenges. This study uses a novel and generalized approach for automated LD and IAD measurement based on a combination of spatial transformation and scale-space. In this iterative procedure, the scale-space is first used to get the lumen axis which is then used with spatial image transformation paradigm to get a transformed image. The scale-space is then reapplied to retrieve the lumen region and boundary in the transformed framework. Then, inverse transformation is applied to display the results in original image framework. Two hundred and two patients’ left and right common carotid artery (404 carotid images) B-mode ultrasound images were retrospectively analyzed. The validation of our algorithm has done against the two manual expert tracings. The coefficient of correlation between the two manual tracings for LD was 0.98 (p < 0.0001) and 0.99 (p < 0.0001), respectively. The precision of merit between the manual expert tracings and the automated system was 97.7 and 98.7%, respectively. The experimental analysis demonstrated superior performance of the proposed method over conventional approaches. Several statistical tests demonstrated the stability and reliability of the automated system. © 2016, International Federation for Medical and Biological Engineering.
