  • Item
    E-field computation in 765 kV substation using CSM with reference to occupational exposure
    (Institution of Engineering and Technology journals@theiet.org, 2018) Devarajan, D.; Punekar, G.S.; Bhatt, N.S.
    With the increase in transmission voltage level, and the guidelines of the International Commission on Non-Ionising Radiation Protection (ICNIRP), the effects of non-ionising radiation on biological elements at high-voltage substations have gained significant importance. The electric field (E-field) distribution in an upcoming 765 kV substation in the Indian subcontinent is computed using the charge simulation method (CSM). CSM is used to model the 765 kV bays, transmission lines, buses, and ground wires in the substation. The three-dimensional (3D) E-field is calculated through the superimposition of E-fields obtained in two orthogonal planes using infinite-line charges. This proposed method of using infinite-line charges gives realistic results. The simplistic model using infinite-line charges greatly reduces the complexity of the CSM-based model (due to the reduced number of charges) apart from increasing the CSM-based model accuracies. This fact has been demonstrated by comparing these results with those of CSM-3D-model of a detailed bay model (including major equipment and associated support structures). The complex-charge-based CSM helps in computing the root mean square value of the E-field at a point, directly, as per ICNIRP guidelines. This RMS value of the E-field is compared with the occupational exposure reference value prescribed in the ICNIRP guidelines. © The Institution of Engineering and Technology 2017.
  • Item
    Electric Field Reduction in an EHV Substation for Occupational Exposure via Transposition of Conductors
    (Institute of Electrical and Electronics Engineers Inc., 2018) Devarajan, D.; Punekar, G.S.
    An attempt is made to reduce the maximum value of rms electric field (E-field) via the transposition of conductors in a 765-kV substation with reference to the occupational exposure. The method is applied to a extra-high-voltage substation, which is under construction. The effect of transposing the bay conductors (alone) and the bus conductors (alone) on the E-field distribution (at 2 m above the ground) over the area of the substation is discussed. Also, the topology of substation conductors that results in the minimum value for the maximum of rms E-fields is obtained via simultaneous transpositions of the bus and bay conductors. The area of the substation where the rms E-field exceeds the reference value of 10 kV/m (International Commission on Non-Ionizing Radiation Protection occupational exposure limit) is also reported for the existing topology. For this topology, the computed maximum value of the rms E-field over the area of the substation is 13.06 kV/m. This E-field is reduced to 7.999 kV/m with the best configuration of substation conductors obtained via transposition. The charge-simulation-method-based generalized algorithm for obtaining the best topology (among all permutations) of substation conductors, which results in the minimum value for the maximum of rms E-field magnitudes over the substation area is also reported. © 1986-2012 IEEE.
  • Item
    GA-CSM based optimized clearances for the reduction of occupational exposure in EHV substation☆
    (Elsevier Ltd, 2023) Devarajan, D.; Punekar, G.S.
    The magnitude of the electric field (E-field) in a 765 kV substation is reduced by altering the conductor clearances in view of the occupational exposure limits. Multi-objective genetic algorithm (GA) along with the charge simulation method (CSM) is utilized in arriving at the optimal clearances of the substation conductors. An EHV substation is modeled with the dimensions and the clearances as in the actual layout of a substation. The E-field results obtained using the finite-line based modeling and infinite-line based modeling of conductors, are compared in terms of the model accuracy and the computational time. The advantages of using the infinite-line based CSM model in view of the occupational exposure is detailed. With the proposed GA-CSM routine, the maximum value of the E-field in the substation is reduced to 10 kV/m (from the existing value of 13 kV/m). The proposed method is used with the existing topology and the best possible transposed topology to obtain the modified layouts. A novel EHV substation layout with different ground clearances for the inner bays and the outer bays is presented. The GA-CSM routine proposed in this work is applicable to any EHV substation with the multiple conductor arrangements. © 2022