Faculty Publications

Permanent URI for this communityhttps://idr.nitk.ac.in/handle/123456789/18736

Publications by NITK Faculty

Browse

Search Results

Now showing 1 - 2 of 2
  • Item
    Analytical computation of gwp, odp, rf number and tewi analysis of various r134a/r1270/r290 blends as r22 alternatives
    (CRC Press/Balkema, 2018) Vali, S.S.; Ashok Babu, T.P.
    The principal objective of the present work is to compute the GWP, ODP, RF number and TEWI analysis of various ternary R134a/R1270/R290 blends as alternatives to R22. In this study thirteen refrigerant blends consists of R134a, R1270 and R290 at different compositions are taken. GWP and ODP of refrigerant blends are computed by using various simple correlations. The estimation of emission of greenhouse gases and flammability study of refrigerants are done by using TEWI and RF analysis respectively. Analytical results revealed that all the thirteen studied fluids are ozone friendly in nature. The GWP of refrigerant M6 (651) is lower than that of GWP of R22 (1760). RF analysis exhibited that all the thirteen refrigerant blends are categorized as ASHRAE A2 flammability category. Thermodynamic analysis revealed that COP of M6 (3.608) is higher that of COP of R22 (3.534). TEWI of M6 is lower among the R22 and thirteen studied fluids. Hence refrigerant M6 (R134a/R1270/R290 50/5/45 by mass%) is an alternative to R22. © 2018 Taylor & Francis Group, London.
  • Item
    Analytical computation of thermodynamic performance of various new eco-friendly alternative refrigerants applicable for air conditioners
    (Springer Science and Business Media Deutschland GmbH info@springer-sbm.com, 2021) Vali, S.V.; Ashok Babu, T.P.; Mahapatra, D.; Saboor, S.; Gorantla, K.K.; Sai Siva Subramanyam, V.
    The objective of the present investigation is to do the theoretical thermodynamic analysis of various new eco-friendly R22 substitutes used in vapour compression refrigeration (VCR) cycle. In this work, nine mixture refrigerants were considered at different compositions. Thermodynamic properties of all the considered refrigerants were developed and the same properties were used in the performance analysis of alternative refrigerants. Standard VCR cycle was considered for the thermodynamic assessment of alternative refrigerants. The working conditions considered are expressed as Te = 7.2 °C, Tk = 54.4 °C, ΔTsup = 11.1 °C and ΔTsub = 8.3 °C, respectively. Results revealed that the COP of mixture refrigerant MR20 (R600a/R134a/R1270 5/47.5/47.5 in mass%) was 2.02% higher than the COP of R22 and other nine investigated refrigerants. Discharge temperature of compressor obtained for MR20 was 11.79 °C lower compared to that of R22. Compressor power obtained for MR20 was 1.96% lower than that of R22. Volumetric refrigeration capacity obtained for MR20 was relatively closer to that of R22. GWP100 of MR20 (619) was lower compared to the GWP100 of R22 (1760). Overall, the performance of mixture refrigerant MR20 was better compared to all the considered R22 alternatives, and therefore it might be an appropriate candidate to replace R22 used in air conditioners. © Springer Nature Singapore Pte Ltd 2021.