  • Item
    Genetic algorithm in location identification of AEPD source: Some aspects
    (IEEE Computer Society, 2013) Punekar, G.S.; Antony, D.; Bhavanishanker, T.; Nagamani, H.N.; Kishore, N.K.
    Using the experimental data obtained from an Acoustic Emission Partial Discharge (AEPD) system, efforts are made to locate the source of Partial discharge (PD) with a transformer tank. The AEPD data with 8 sensors (available in the literature) is numerically experimented with a Genetic Algorithm, although minimum of 4 sensors only are necessary for identifying the location. With eight sensors, four sensors considered at a time, form 70 ( 8C4) combination of sensors. The effect, implication and usage of superfluous sensor data in identifying the location with GA is analyzed and reported. Results are compared with Newton's method. © 2013 IEEE.
  • Item
    Improvements in AEPD location identification by removing outliers and post processing
    (Institute of Electrical and Electronics Engineers Inc., 2016) Antony, D.; Punekar, G.S.
    The mathematical model of an Acoustic Emission Partial Discharge (AEPD) system is solved in the literature using Newton's method with redundant number of sensors (more than 4; eight in this case). The system for numerical experiments consists of eight sensors. The algorithm is implemented using three different initial guesses. For the calculated PD source coordinates, histograms are plotted. After finding the mean and standard deviation, coordinate values which are lying outside different fractions of sigma are removed. The average of remaining set is calculated and it is found that, the accuracy of location identification can be greatly improved. © 2015 IEEE.
  • Item
    Case studies on transformer fault diagnosis using dissolved gas analysis
    (IEEE Computer Society, 2017) Shanker, T.B.; Nagamani, H.N.; Antony, D.; Punekar, G.S.
    In this paper the results of dissolved gas analysis (DGA) along with details of the DGA data from in-service transformers are discussed. Two case studies are given of which, first case study deals with the detection of the partial discharge and the second case study deals with the detection of thermal fault in transformers at thermal power stations in India. The interpretation of DGA data are conducted using key gas method. The interpretations are validated by the application of gas ratio method. Gas ratio method included in this study are Rogers ratio and Doernenburg ratio. © 2017 IEEE.
  • Item
    Effects of error in time-delay on AEPD source localization using Newton's method: Numerical experimentation
    (Institute of Electrical and Electronics Engineers Inc., 2017) Antony, D.; Punekar, G.S.; Kishore, N.K.
    Newton's method is one of the commonly used methods for acoustic emission partial discharge (AEPD) source localization in power transformers. The major problem in the AEPD source localization is the difficulty in accurately measuring the signal arrival time from the source to the multiple sensors. The exact instant at which the partial discharge (PD) occurs is not known. Therefore, instead of the absolute time, the time-delay in signal reception of each sensor with respect to the sensor nearest to the PD source is estimated. In the present study the effect of time-delay error on the accuracy of the PD source localization is analyzed through numerical experimentations. The solution of the Newtons's method in turn depends on the choice of the initial guess. Hence, different initial guesses are selected for Newton's method randomly. For a fixed set of coordinates for the four sensors and the PD source positions, the time-delays are theoretically calculated. The error is systematically increased in the calculated time-delay to form different groups of time-delays. The PD source is localized using each initial guess for all the groups of time-delays to analyze the effect of error in time-delay on accuracy of PD source localization. The error in time-delay greatly affects the AEPD source localization. Moreover, if Newton's method with a bad initial guess is used then the errors in AEPD source localizations are not systematic. © 2017 IEEE.
  • Item
    Identification of invalid time-delay-groups using discriminant and Jacobian-determinant in acoustic emission PD source localisation
    (Institution of Engineering and Technology journals@theiet.org, 2017) Antony, D.; Punekar, G.S.
    The key problem in locating a source of partial discharge (PD) using the acoustic emission technique is the error in estimating the signal arrival time from the source to the multiple sensors. When the time difference of arrival approach is used for the PD-source-localisation, some of the measured time-delay-groups will have solution for the time-difference equation in the complex-number-field. This is due to the significant error in the arrival time estimation. Such time-delay-groups should be considered to be invalid. In this study, a function is proposed for identifying the invalid time-delay-groups for the fixed set of coordinates of four sensors and the specific velocity of the acoustic signal used. The negative sign of this function value indicates that the solution is in the complex-number-field. An alternative method for identifying the invalid time-delay-groups is by using Newton's method. The multiple sign changes of the Jacobian-determinant in the iterations of Newton's method shows that the solution is in the complex-number-field. The proposed methods have been tested with data from the existing literature, and results have confirmed the efficacy of these methods in the identification of the invalid time-delay-groups. Discarding such groups of time delays improves the accuracy of statistical PD-source-localisation. © 2016, The Institution of Engineering and Technology.
  • Item
    Noniterative Method for Combined Acoustic-Electrical Partial Discharge Source Localization
    (Institute of Electrical and Electronics Engineers Inc., 2018) Antony, D.; Punekar, G.S.
    The combined acoustic-electrical system is used in the factory or plant environment for the partial discharge (PD) source localization in power transformers. A noniterative method for this combined acoustic-electrical PD-locator-system is devised and presented in this paper for the first time. It employs three acoustic emission (AE) sensors. The proposed method is compared with the existing noniterative method used in the all-acoustic system, which employs four AE sensors. The comparative study shows that the proposed method can locate the PD source irrespective of its position within the tank, whereas the prevailing noniterative method for the all-acoustic system fails to locate the PD source at certain positions within the tank. The effect of the sensor positioning on the performance of the method is studied, and some guidelines for the sensor placement on the transformers tank wall in a factory or plant environment are suggested. The proposed method is also applied to the data taken from the published literature. The localization results are compared with those of an existing iterative method (Newton's method) to prove its superiority in terms of computational time. © 1986-2012 IEEE.
  • Item
    Effects of transformer-oil temperature on amplitude and peak frequency of partial discharge acoustic signals
    (Institute of Electrical and Electronics Engineers Inc., 2018) Shanker, T.B.; Nagamani, H.N.; Antony, D.; Punekar, G.S.
    The behavior of partial discharge (PD) acoustic emission (AE) signals in the transformer oil for a temperature range of 30-75 °C is studied via laboratory experiments. The AE signals are analyzed using the fast Fourier transform (FFT) to obtain the peak frequency and the AE amplitude. A peculiar behavior of reduction in the peak frequency and the AE amplitude observed above 65 °C is reported. An attempt is made to explain the reduction in the AE amplitude after a certain temperature by correlating it with the properties of the transformer oil such as the viscosity and the breakdown voltage. This AE signal analysis is perhaps an important advancement in the PD diagnosis and the PD spectrum analysis at different temperatures in the transformer oil. © 1986-2012 IEEE.