Faculty Publications

Permanent URI for this communityhttps://idr.nitk.ac.in/handle/123456789/18736

Publications by NITK Faculty

Browse

Search Results

Now showing 1 - 2 of 2
  • Item
    Semi-active vibration control of SiC-reinforced Al6082 metal matrix composite sandwich beam with magnetorheological fluid core
    (SAGE Publications Ltd info@sagepub.co.uk, 2020) Allien, J.V.; Kumar, H.; Desai, V.
    Dynamic characterization of silicon carbide particles reinforced Al6082 alloy metal matrix composite sandwich beam with magnetorheological fluid core is experimentally investigated. The study is focused on determining the effect of magnetorheological fluid core on the dynamic behavior of the sandwich structure. The magnetorheological fluid core is enclosed between the top and bottom metal matrix composite beams. The metal matrix composite beams are cast with silicon carbide particles in Al6082 alloy varying from 0 to 20 wt%. The magnetorheological fluid is prepared in-house and contains 30 vol.% carbonyl iron powder and 70 vol.% silicone oil. The free vibration test is conducted to determine the natural frequencies and damping ratio. It is found that the natural frequencies and damping ratio of the sandwich beams increased with an increase in the applied magnetic flux density. The experimental forced dynamic response of sandwich beams is carried out using sine sweep excitation. Vibration amplitude suppression capabilities of the sandwich beams subjected to varying magnetic flux densities are determined. The experimental forced vibration results reveal that metal matrix composite–magnetorheological fluid core sandwich beams have excellent vibration amplitude suppression capabilities. © IMechE 2019.
  • Item
    Semi-active vibration control of MRF core PMC cantilever sandwich beams: Experimental study
    (SAGE Publications Ltd info@sagepub.co.uk, 2020) Allien, J.V.; Kumar, H.; Desai, V.
    The semi-active vibration control of sandwich beams made of chopped strand mat glass fiber reinforced polyester resin polymer matrix composite (PMC) and magnetorheological fluid (MRF) core were experimentally investigated in this study. Two-, four- and six-layered glass fiber reinforced polyester resin polymer matrix composites were prepared using the hand-layup technique. The magnetorheological fluid was prepared in-house with 30% volume of carbonyl iron powder and 70% volume of silicone oil. Nine cantilever sandwich beams of varying thicknesses of the top and bottom layers glass fiber reinforced polyester resin polymer matrix composite beams and middle magnetorheological fluid core were prepared. The magnetorheological fluid core was activated with a non-homogeneous magnetic field using permanent magnets. The first three modes, natural frequencies and damping ratios of the glass fiber reinforced polyester resin polymer matrix composite-magnetorheological fluid core sandwich beams were determined through free vibration analysis using DEWESoft modal analysis software. The amplitude frequency response of the glass fiber reinforced polyester resin polymer matrix composite-magnetorheological fluid core sandwich beams through forced vibration analysis was determined using LabVIEW. The effect of various parameters such as magnetic flux density, thickness of glass fiber reinforced polyester resin polymer matrix composite layers and magnetorheological fluid core layer on the natural frequencies, damping ratio and vibration amplitude suppressions of the glass fiber reinforced polyester resin polymer matrix composite-magnetorheological fluid core sandwich beams was investigated. Based on the results obtained, 2 mm thickness top and bottom layers glass fiber reinforced polyester resin polymer matrix composite and 5 mm thickness magnetorheological fluid core sample have achieved a high shift in increased natural frequency, damping ratio and vibration amplitude suppression under the influence of magnetic flux density. © IMechE 2020.