Journal Articles
Permanent URI for this collectionhttps://idr.nitk.ac.in/handle/123456789/19884
Browse
25 results
Search Results
Item Environmental sustainability of waste glass as a valuable construction material - A critical review(EM International rktem@pn3.vsnl.net.in, 2018) Sudharsan, N.; Palanisamy, T.; Yaragal, S.C.The increased demand for concrete as a construction material leads to increase in cement production. The formulation of cement, emits a significant amount of CO2 to the atmosphere, which causes severe environmental pollution. Many efforts are being made to reduce the use of Portland cement in concrete to avoid environmental issues. These efforts mainly involve the utilization of value added materials in concrete. In this context, the waste glass powder has excellent pozzolanic properties, to use glass powder as a supplementary cementitious material in concrete. The use of waste glass powder in concrete has many economic and environmental benefits. This paper summarizes the literature regarding the utilization of waste glass powder as a supplementary cementitious material in mortar and concrete. © 2018 EM International. All rights reserved.Item Studies on concrete cylinders subjected to elevated temperatures(2010) Babu Narayan, K.S.; Anil Kumar, G.; Chandrakala, C.; Shashikumar, H.M.; Venkataramana, K.; Yaragal, S.C.; Chinnagiri Gowda, H.C.; Reddy, G.R.; Sharma, A.Concrete is a poor conductor of heat, but can suffer considerable damage when exposed to fire. Concrete in structures is likely to be exposed to high temperatures during fire. The relative properties of concrete after such an exposure are of great importance in terms of the serviceability of buildings. Unraveling the heating history of concrete is important to forensic research or to determine whether a fire exposed concrete structures and its components are still structurally sound or not. Assessment of fire damage concrete structures usually starts with visual observation of color change, cracking and spalling. On heating, a change in color from normal to pink is often observed and this is useful since it coincides with the onset of significant loss of concrete strength. This work reports the characteristics of concrete at elevated temperatures. Popular normal strength grades (M20, M25, M30, M35, M40 and M45) produced by Ready Mix Concrete (RMC) India, Mangalore have been used in production of test specimens (150 mm diameter and 300mm height cylinders) to obtain more meaningful and realistic data. In the preliminary phase 150 mm diameter and 300mm height cylinders were cast, cured and tested by destructive method for gathering data on strength characteristics. Later these test samples were subjected to elevated temperatures ranging from 100°C to 800°C, in steps of 100°C with a retention period of 2 hours. After exposure, weight losses were determined and then again destructive tests were conducted to estimate the residual split tensile strength. Test results indicated that weight and strength significantly reduces with an increase in temperature. © 2010 CAFET-INNOVA TECHNICAL SOCIETY. All rights reserved.Item Strength retention characteristics of concrete cubes subjected to elevated temperatures(2010) Yaragal, S.C.; Clarke, K.S.; Mahesh Babu, K.; Ashokumar, S.; Venkataramana, K.; Babu Narayan, K.S.; Chinnagiri Gowda, H.C.; Reddy, G.R.; Sharma, A.Concrete in structures is likely to be exposed to high temperatures during fire. The relative properties of concrete after such an exposure are of great importance in terms of the serviceability of buildings. The probability of its exposure to elevated temperatures is high due to natural hazards, accidents and sabotages. Therefore, the performance of concrete during and after exposure to elevated temperature is a subject of great interest to the designer. Physical changes like cracking, colour change, spalling and chemical changes like decomposition of Ca(OH)2 and the C-S-H gel take place when subjected to elevated temperatures. This work reports the characteristics of concrete at elevated temperatures. Popular normal strength grades (M20, M25, M30, M35, M40 and M45) produced by Ready Mix Concrete (RMC) India, Mangalore have been used in production of test specimens (150 mm cubes) to obtain more meaningful and realistic data. In the preliminary phase 150 mm cubes were cast, cured and tested by destructive method for gathering data on strength characteristics. Later these test samples were subjected to elevated temperatures ranging from 100°C to 800°C, in steps of 100°C with a retention period of 2 hours. After exposure, weight losses were determined and then again destructive tests were conducted to estimate the residual compressive strength. Test results indicated that weight and strength significantly reduces with an increase in temperature. © 2010 CAFET-INNOVA TECHNICAL SOCIETY.Item Studies on normal strength concrete cubes subjected to elevated temperatures(2010) Yaragal, S.C.; Babu Narayan, K.S.; Venkataramana, K.; Kulkarni, K.S.; Gowda, H.C.C.; Reddy, G.R.; Sharma, A.Concrete in structures is likely to be exposed to high temperatures during fire. The probability of its exposure to elevated temperatures is high due to natural hazards, accidents and sabotages. Therefore, the performance of concrete during and after exposure to elevated temperature is a subject of great importance and interest to the designer. Popular normal strength grades of concrete produced by Ready Mix Concrete (RMC) India, Mangalore have been used in production of test specimens (150 mm cubes), cured and tested by destructive method for gathering data on strength characteristics. Later, these test samples were subjected to elevated temperatures ranging from 100 C to 800 C, in steps of 100 C with a retention period of 2 hours. After exposure, weight losses and the residual compressive strength retention characteristics are studied. Test results indicated that weight and strength significantly reduces with an increase in temperature. Residual compressive strength prediction equations are proposed for normal strength concretes subjected to elevated temperatures.Item Characteristics of normal strength concrete with and without chemical admixtures at elevated temperatures(CAFET INNOVA Technical Society 1-2-18/103, Mohini Mansion, Gagan Mahal Road, Domalguda, Hyderabad 500029, 2011) Yaragal, S.C.; Warad, S.A.; Babu Narayan, K.S.; Venkataramana, K.Fire is one of the most destructive powers to which a building structure can be subjected. Behavior of concrete when exposed to fire in cases like nuclear plants, cooling towers or any accidental fire in industrial buildings, is a serious concern, on the strength retention property of concrete. This work reports strength retention studies on compressive and split tensile strength of normal concrete with and without the chemical admixture (Reobuild 918, BASF make) at elevated temperatures. Concrete cubes of size 100 mm have been cast as per prior mix design for M30 grade of concrete, 28 days water cured and tested by destructive method for strength before exposure. Later these specimen were subjected to elevated temperatures of 200°C, 400°C, 600°C and 800°C with a retention period of 2 hours and were allowed cool within the furnace to reach ambient temperature. Later their appearance, colour and cracks were observed and also weight losses were determined. Further, destructive tests were conducted to estimate residual compressive and residual split tensile strengths and prediction equations are proposed to ascertain splitting tensile strengths from compressive strengths. © 2011 CAFET-INNOVA TECHNICAL SOCIETY. All rights reserved.Item Effect of recuring on compressive strength of thermally deteriorated concrete cubes(2011) Prasanth, S.; Yaragal, S.C.; Babu Narayan, K.S.Concrete is found to undergo degradation when subjected to elevated temperatures during an event such as fire and lose substantial amount of its strength. The loss of strength in concrete is mainly attributed to decomposition of C-S-H and release of chemically bound water, which begins when the exposure temperature exceeds 500°C. When thermally deteriorated concrete is supplied with water there is a substantive gain in strength as a consequence of rehydration of cement that is initiated. This paper presents results of an experimental program carried out to investigate the effect of recuring on strength gain of normal strength concrete specimens subjected to elevated temperatures from 500°C to 800°C, which were subjected to retention time of two hours at the designated temperatures. © 2011 CAFET-INNOVA TECHNICAL SOCIETY. All rights reserved.Item Usage potential of melt processed plastic pellets as a substitute to fine aggregate in porous concretes(2012) Maneeth, P.D.; Lokesh, G.; Yaragal, S.C.; Babu Narayan, K.S.Porous concrete (PC) has been used for over 30 years. Because of its high porosity, the most common usages have been in the area of storm water management, but have been limited to use in pavements with low volume traffic, because of its low compressive strength compared to conventional concrete. Domestic and industrial plastic waste management has posed a serious challenge to engineers and scientists today. In this study an attempt is made to utilize plastic waste (melt processed) from small industries as a substitute for fine aggregate (up to 10%) in producing porous concretes. The recycled plastic (melt processed) was produced by drawing industrial and domestic waste plastic into long strands which were cut to small pieces forming granules. The plastic granules (pellets) are used as substitute to sand in this investigation. This experimental investigation reports the scope for plastic waste utilization as a substitute for fine aggregate and its influence on properties like porosity, permeability, compressive strength and tensile strength of porous concretes. © 2012 CAFET-INNOVA TECHNICAL SOCIETY. All rights reserved.Item Strength characteristics of concrete exposed to elevated temperatures and cooled under different regimes(2012) Yaragal, S.C.; Babu Narayan, K.S.; Adari, S.Concrete loses strength in the event of accidental fires. The residual strength of normal strength concrete is of vital importance for ascertaining serviceability of buildings after the event of fires. Strength loss in concrete is dependent on the temperature of exposure, its duration and the way it gets cooled. In this study concrete cubes of size 100 mm have been cast for M25 grade of concrete, 28 days water cured. The specimens were subjected to elevated temperatures of 150°C, 250°C, 350°C, 450°C and 550°C with a retention period of 1 hour. After 1 hour of exposure, specimens were allowed to cool under different cooling regimes to ambient temperature. Later their appearance, colour and cracks were observed and also weight losses were determined. Further, destructive tests were conducted to estimate residual compressive and split tensile strengths. Important performance changes have been presented and discussed. Split tensile strengths are related to compressive strengths for all the cases of cooling regimes.Item Recuring studies on concretes subjected to elevated temperatures and suddenly cooled by water quenching(Multi-Science Publishing Co. Ltd, 2015) Yaragal, S.C.; Kittur, M.M.; Babu Narayan, K.S.Concrete is found to undergo degradation when subjected to elevated temperatures during an accidental event, such as fire and lose substantial amount of its original strength. The loss of strength in concrete is mainly attributed to the decomposition of Calcium Silicate Hydrate (C-S-H) and release of chemically bound water, which begins when the exposure temperature exceeds 500°C. When such a concrete is supplied with water and allowed to recure, it is found to recover substantial amount of its lost strength. This work is carried out to investigate the effect of recuring on strength recovery of un-blended and blended concrete specimen (100 mm cubes) subjected to elevated temperatures from 400°C to 700°C, in steps of 100°C, for a retention period of two hours at the designated temperatures. The concrete cubes immediately after exposure were subjected to thermal shock by quenching them in water, and then temperature of thermally shocked concrete is allowed to cool to room temperature. The cooled specimen were then recured in water for 1, 3, 7, 14, 21, 28, 56 days and tested for compressive strength recovery. These studies were carried out for Portland Cement (PC) based concrete and Portland & Granulated Blast Furnace Slag (70% PC + 30% GGBS) based concrete (blended concrete), and some interesting results are presented and discussed in this paper. © 2015, Multi-Science Publishing Co. Ltd. All rights reserved.Item Performance of hybrid fibre-reinforced concretes at elevated temperatures(Emerald Group Holdings Ltd., 2017) Shirsath, S.K.; Yaragal, S.C.Purpose – This study reports the performance of thermally deteriorated concrete with and without fibres. Attempts have been made to find the suitable performance of steel polypropylene (PP) hybrid fibre combination that could significantly enhance the performance of mechanical properties at elevated temperatures. Design/methodology/approach – In this experimental investigation, concrete cubes of 100 mm in size of various compositions were cast and water-cured for 28 days, and later exposed to elevated temperatures of either 200 or 400°C or 600 and or 800°C with a retention period of 2 h. The properties like change in colour and percentage weight loss were evaluated. Ultrasonic Pulse Velocity test was used to obtain qualitative information of strength variation. Residual strength of thermally deteriorated concrete specimen was measured by destructive testing. Findings – Steel fibre volume fraction of 1 per cent improves the compressive strength of concrete in the temperature range of 400 to 800°C. The addition of steel fibre and PP fibre (Mix 3) improves the splitting strength of the concrete at elevated temperature range of 400 to 600°C. Originality/value – Performance enhancement is observed with hybrid fibres for temperature endurance of concrete. © Emerald Publishing Limited.
- «
- 1 (current)
- 2
- 3
- »
