Journal Articles

Permanent URI for this collectionhttps://idr.nitk.ac.in/handle/123456789/19884

Browse

Search Results

Now showing 1 - 10 of 18
  • Item
    Crop pattern change and crop water requirement judgment using remote sensing and gis techniques: A research on tungabhadra dam right canal
    (Blue Eyes Intelligence Engineering and Sciences Publication, 2019) Yadav, A.; Hafeezunnisa; Kappadi, P.
    Agriculture is most important resources of any country worldwide which is a major renewable source and is dynamic. The study area selected was command area under Basavanna canal which is one of the canals to Tungabhadra river on right side bank. This selected canal for cropping pattern analysis has a command of 1240.00 hectare and is located at Vallabhpur, Bellary district. Basavanna canal has a designed discharge capacity of 125 cusecs for serving the cropping area. Every irrigation project has planned cropping pattern, the crop water requirement (CWR) for which is calculated based on Duty / Delta method. However due to growing population and increase demand for food products crop violation is found in every command leading to more irrigation. Remote Sensing (RS) and Geographical Information System (GIS) techniques have emerged as powerful tools for crop water management. Remotely sensed land use-land cover data was used for analysing the cropping pattern in the area and also to estimate the change in the cropping pattern. This study was performed using ArcGIS 9.3 and ERDAS 9 software. Crop water requirement was calculated using Modified Penman Equation for present cropping pattern. The study finds that, approximately 50% of water could be saved using modified Penmen method compared to crop water requirement calculated using Duty Delta method as adopted in project report and the same water may be diverted to meet other needs. © BEIESP.
  • Item
    Effect of exhaust gas recirculation rate on performance, emission and combustion characteristics of a common-rail diesel engine fuelled with n-butanol–diesel blends
    (Taylor and Francis Ltd. michael.wagreich@univie.ac.at, 2020) Lamani, V.T.; Yadav, A.; Gottekere, K.N.
    Increasing fears of fossil fuel attenuation and tough emission protocols compel the research community to explore alternative renewable fuels for diesel engines. Butanol is desirable among renewable fuels due to its properties favorable to diesel engines. This study focused on the suitability of exhaust gas recirculation (EGR) and optimum injection timing on the performance, combustion and exhaust emission characteristics of common-rail direct-injection (CRDI) engine fueled with n-butanol-blended diesel using experimental and computational fluid dynamics (CFD) simulation. Various EGR rates and injection timings are considered for different butanol–diesel blends (0, 10, 20 and 30%). Obtained simulation results are validated with experimental data and found to be in good agreement. For all EGR rates and blends, nitrogen oxide (NO) emission is reduced drastically, whereas carbon monoxide (CO) and soot emissions are decreased moderately, with increase in n-butanol–diesel blends. The CO and soot emissions increase with EGR rate due to oxygen deficiency as well. Brake thermal efficiency is reduced by approximately 1% for neat diesel (Bu0) with increase in EGR rates. Soot emission for Bu30 (15 ° Before top dead centre (BTDC) is decreased by 23, 25, 24 and 26% for 0, 10, 20 and 30% EGR rates, respectively, compared to Bu0 (12° BTDC). © 2017, © 2017 Informa UK Limited, trading as Taylor & Francis Group.
  • Item
    Numerical and experimental investigation of melting characteristics of phase change material-RT58
    (Elsevier Ltd, 2020) Yadav, A.; Donepudi, T.; Siddani, B.S.
    The present study is focused on experimental and numerical analysis of unconstrained melting of Paraffin wax-RT58 in a horizontally placed cylindrical container. After the validation of numerical model with experimental results, numerical analysis is extended to constrained melting to investigate the process. The experiments are carried out at constant wall temperature maintained on the lateral surface of the cylinder. The influence of initial sub-cooling and lateral surface temperature on the melting rate is investigated. The melting process is better analyzed by the melting phase front and temperature contours as time progresses. The results show that the melting rate decreases by increasing the initial sub-cooling, and increases with increasing lateral surface temperature of the cylinder. In unconstrained melting, heat transfer by conduction governs the melting process initially, but later it is restricted to only the bottom part of the cylinder as the solid PCM at a higher density sinks due to effects of gravity. Heat transfer in the upper half of the cylinder is dominated by natural convection set up in the liquid PCM. In constrained melting, pure conduction phenomenon exists only in the beginning, and later conjugate heat transfer occurs. When subjected to similar boundary conditions, PCM melt-time is lower in unconstrained melting than in constrained melting. A correlation between melt-time and Stefan number is also developed. © 2019 Elsevier Ltd
  • Item
    Enhanced thermo-hydraulic performance in a V-ribbed triangular duct solar air heater: CFD and exergy analysis
    (Elsevier Ltd, 2020) Nidhul, K.; Kumar, S.; Yadav, A.; Anish, S.
    Computational fluid dynamics (CFD) and exergy analysis are conducted to investigate the impact of secondary flow produced by V-ribs on the overall performance of a triangular solar air heater (SAH) duct. For a fixed relative rib pitch (Rp = 10) and relative rib height (Rh = 0.05), the effect of rib inclination (?) is studied using CFD technique for varying Reynolds number (5000 ? Re ? 20000). Based on the CFD simulation results, empirical correlations capable of predicting Nu and f with an absolute variance of 8.7%, and 4.7%, respectively, are developed. Employing these correlations, exergetic performance analysis is carried out. Maximum effectiveness parameter (?) of 2.01 is obtained for ? = 45° at Re = 7500. The exergy analysis reveals that the entropy generated is lower for the ribbed triangular duct compared to the smooth duct with maximum enhancement in exergetic efficiency (?ex) as 23% for ? = 45°. The study is extended for the rectangular duct to compare the performance with the ribbed triangular duct SAH (? = 45°). Results show that ribbed triangular duct SAH (? = 45°) is superior over various configurations of the ribbed rectangular duct SAH at higher mass flow rates. © 2020 Elsevier Ltd
  • Item
    Efficient design of an artificially roughened solar air heater with semi-cylindrical side walls: CFD and exergy analysis
    (Elsevier Ltd, 2020) Nidhul, K.; Yadav, A.; Anish, S.; Arunachala, U.C.
    Solar air heater (SAH) with semi-cylindrical sidewalls and W-baffles is analyzed for energy and exergy efficiency in the turbulent flow regime. Computational fluid dynamics (CFD) analysis is carried out for a fixed baffle inclination (?) and varying the relative baffle height (Rh = e/D) and relative baffle pitch (Rp = P/D) in the range 0.046–0.115 and 0.46–1.15, respectively. For Reynolds number (5000 < Re < 17,500), the numerical methodology is substantiated using experimental and theoretical correlations obtained from the literature. Smaller vortices near the sharp corners are removed by rounding the sharp edges, allowing the flow of fluid from inside and horizontal walls of the duct towards the semi-cylindrical sidewalls. This increases the overall turbulent kinetic energy. A peak augmentation of 3.24 and 4.03 times is obtained for Nusselt number (Nu) and friction factor (f), respectively, in contrast to conventional SAH. With a maximum enhancement of 127% in the effectiveness parameter relative to smooth SAH, this novel SAH design is evidently energy efficient. Based on CFD results, new correlations are developed in terms of Rh and Rp, which predicts the values with an absolute deviation of 4% and 7.4%, respectively. With lower exergy destruction, maximum enhancement in thermal and exergetic efficiency is obtained as 40.7% and 95.4%, respectively, for the proposed SAH relative to conventional SAH. Upon comparison with ribbed rectangular duct SAH configurations, the present design with semi-cylindrical side walls outperforms at all flow Re. © 2020 International Solar Energy Society
  • Item
    Comparative computational appraisal of supercritical CO2-based natural circulation loop: effect of heat-exchanger and isothermal wall
    (Springer Science and Business Media B.V., 2020) Thimmaiah, S.; Wahidi, T.; Yadav, A.; Mahalingam, A.
    Natural circulation loop (NCL) is a geometrically simple heat transfer device in which fluid flow occurs due to density gradient of loop fluid, induced by the temperature difference between the source and the sink. NCL has an inherent problem of instability caused by the combined effect of buoyancy, friction and inertia forces at varying operating conditions, and hence it requires an elegant solution of instability. The primary objective of the present work is to do a comparative study on the dynamic performance between two different configurations of NCL based on supercritical CO2, i.e. (i) NCL with isothermal heater and a cold heat-exchanger (ISO-CHX), and (ii) NCL with hot and cold heat-exchangers (HHX-CHX). To explore these NCLs, two-dimensional transient computational fluid dynamics studies have been carried out on the stability of supercritical CO2-based natural circulation loop. Results are obtained for different operating pressures and temperatures in the form of mass flow rate and velocity variation with respect to time. Results show the higher instabilities in both side heat-exchanger loop than an isothermal heater with heat-exchanger loop. At a lower rate of heat input at source in the HHX-CHX loop, the mass flow is bidirectional, whereas it is unidirectional in the ISO-CHX loop at all level of heat input. It is also observed that as pressure increases, flow instability also increases. Obtained results are validated with the published experimental and numerical data and found in good agreement. © 2020, Akadémiai Kiadó, Budapest, Hungary.
  • Item
    Combustion, performance and emission analysis of preheated KOME biodiesel as an alternate fuel for a diesel engine
    (Springer Science and Business Media B.V., 2020) Kodate, S.V.; Yadav, A.; Kumar, G.N.
    In the present work, karanja oil methyl ester (KOME) biodiesel is used in a compression ignition engine to find an alternative to diesel. The use of biodiesel in a CI engine leads to poor performance and high brake specific fuel consumption due to the higher viscosity and lower calorific value of biodiesel. This problem can be reduced by increasing the injection temperature of biodiesel or its blends to a certain temperature. In this study, working fuel is tested at preheating temperatures of 95 °C for various loading conditions (0, 25, 50, 75 and 100%). Effect of different KOME biodiesel–diesel blends (B0, B30, B50 and B100) on engine performance, combustion and emissions is studied at different loads. At higher temperature, the viscosity of the fuel decreases which leads to better combustion, improves the atomization as well as vaporization of fuel in a diesel engine, resulting in higher engine performance and lower emissions of CO and HC, with slight increment in NOX and CO2 emission compared to unheated neat diesel and biodiesel blends. The result shows that for 100% biodiesel (B100) at full load, BTE is improved by 9.1% compared to unheated case. Preheating of B100 fuel upto 95 °C at full load decreases the BSFC, CO and HC emission by 6.5%, 8.1% and 10.6%, respectively, compared to unheated case. © 2020, Akadémiai Kiadó, Budapest, Hungary.
  • Item
    Influence of Rectangular Ribs on Exergetic Performance in a Triangular Duct Solar Air Heater
    (American Society of Mechanical Engineers (ASME), 2020) Nidhul, K.; Kumar, S.; Yadav, A.; Anish, S.
    Several artificial roughness (ribs) configurations have been used in flat plate solar air heaters (SAH) in recent years to improve their overall performance. In the present work, energy and exergy analyses of rectangular ribs in a triangular duct SAH for varying relative rib heights (e/D = 0.02-0.04), relative rib pitches (P/e = 5-15), and rib aspect ratios (e/w = 0.5-4) are evaluated and compared with smooth SAH. The analysis reveals that the entropy generated due to heat transfer is lower for the ribbed triangular duct compared to the smooth duct. It is also observed that the width of the rib plays a crucial role in minimizing heat losses to the environment. A maximum reduction of 43% and 62% in exergy losses to the environment and exergy losses due to heat transfer to the fluid is achieved, respectively, with a rib aspect ratio (e/w) of 4 compared to the smooth plate. It is found that in contrast to the smooth plate, ribs beneath the absorber plate effectively improves thermal and exergetic efficiency. Maximum enhancement of 36% and 17% is obtained in exergetic efficiency (?ex) and thermal efficiency (th), respectively, for e/w = 4, P/e = 10 and e/D = 0.04. Results also show the superiority of the ribbed triangular duct over the ribbed rectangular duct for an application requiring compact SAH with a higher flowrate. © 2020 by ASME.
  • Item
    Computational and experimental studies on the development of an energy-efficient drier using ribbed triangular duct solar air heater
    (Elsevier Ltd, 2020) Nidhul, K.; Kumar, S.; Yadav, A.; Anish, S.
    Triangular duct cross-section is introduced for solar air heater (SAH) of an indirect type of solar dryer (ITSD). Using computational study, the thermo-hydraulic performance of triangular duct SAH with inclined ribs for varying rib inclination (30° < ? < 75°) in the turbulent flow regime (5000 < Re < 17500) is studied. With the rib configuration providing maximum thermos-hydraulic performance, a ribbed rectangular duct SAH is designed, and the performance of the same is compared to the former for similar heat input. Results show that the ribbed (? = 45°) triangular duct has 17% higher effectiveness compared to the latter and 79% when compared to smooth SAH. Ribs in triangular duct solar air heater facilitate the increase in temperature even in the core of the duct, delivering the air at 6 K additional temperature relative to a rectangular ribbed duct for same heat input and flow Re. The superiority of the ribbed triangular SAH is further confirmed by studying the drying characteristics of Okra and two variants of banana, namely Nendran and Robusta for the maximum temperature obtained at the outlet of the respective SAH. Various thin layer drying models available in the literature were analyzed, and Modified page model represented the drying behaviour with R2 = 0.99. For ITSD, ribbed triangular duct SAH exhibits a maximum of 60.3% reduction in moisture ratio with a maximum increase of 97.9% increase in average values of diffusivity coefficient confirming that it is an energy-efficient design for an ITSD. © 2020 International Solar Energy Society
  • Item
    Heat transfer enhancement using CO2 in a natural circulation loop
    (Nature Research, 2020) Thippeswamy, L.R.; Yadav, A.
    The natural circulation loop (NCL) is a highly reliable and noise-free heat transfer device due to the absence of moving components. Working fluid used in the natural circulation loop plays an important role in enhancing the heat transfer capability of the loop. This experimental study investigates the subcritical and supercritical heat transfer performance of a natural circulation loop (NCL) with CO2 as the working fluid. Operating pressures and temperatures are varied in such a way that the loop fluid should remain in the specified state (subcooled liquid, two-phase, superheated vapor, supercritical). Water and methanol are used as external fluids in cold and hot heat exchangers for temperatures above zero and below zero (in °C) respectively, depending on operating temperature. For loop fluids, the performance of CO2 is compared with water for above zero and with brine solution for the subzero case. Further, the impact of loop operating pressure (35–90 bar) on the performance of the system is also studied. For hot heat exchanger inlet temperature (5 to 70 °C) and cold heat exchanger inlet temperature (?18 to 32 °C), it was observed that the maximum heat transfer rates in the case of subcritical vapor, subcritical liquid, two-phase and supercritical CO2 based systems are 400%, 500%, 900%, and 800% higher than the water/brine-based system respectively. © 2020, The Author(s).