Journal Articles

Permanent URI for this collectionhttps://idr.nitk.ac.in/handle/123456789/19884

Browse

Search Results

Now showing 1 - 5 of 5
  • Item
    Critical review of ribbed solar air heater and performance evaluation of various V-rib configuration
    (Elsevier Ltd, 2021) Nidhul, K.; Yadav, A.K.; Anish, S.; Kumar, S.
    The low heat transfer rate in a flat plate solar air heater (SAH) is due to the development of a laminar sub-layer near the heated absorber plate. Owing to this, the plate temperature rises substantially, instigating losses and thus reducing the efficiency. Extensive research has been carried out to mitigate this problem, of which passive technique emerged to be a promising solution. The passive method involves the application of fins/turbulators/ribs on the surface where the boundary layer develops so that it breaks the same. Various profiles and configurations of the ribs ranging from transverse to inclined and continuous to discrete have been presented concisely. Correlations on Nusselt number (Nu) and friction factor (f) for different rib configurations have been summarized in order so that it can be accessed for future research. 3-D CFD analysis is carried out to gain insight into the flow pattern of various V-ribbed SAH, and with the help of streamlines and contours, the findings are established. Furthermore, various exergy destruction has been studied in detail for different V-rib configurations, namely– V-rib, multiple V-rib, and multiple V-rib with the gap, and analyzed in detail for prospective studies. Exergetic performance study of these rib configurations indicates that the multiple ribs and the multiple rib-gap combinations enhance exergetic efficiency (ηex) by 12% and 31.6%, respectively, in comparison to V-rib SAH. © 2021 Elsevier Ltd
  • Item
    Enhanced thermo-hydraulic performance in a V-ribbed triangular duct solar air heater: CFD and exergy analysis
    (Elsevier Ltd, 2020) Nidhul, K.; Kumar, S.; Yadav, A.; Anish, S.
    Computational fluid dynamics (CFD) and exergy analysis are conducted to investigate the impact of secondary flow produced by V-ribs on the overall performance of a triangular solar air heater (SAH) duct. For a fixed relative rib pitch (Rp = 10) and relative rib height (Rh = 0.05), the effect of rib inclination (?) is studied using CFD technique for varying Reynolds number (5000 ? Re ? 20000). Based on the CFD simulation results, empirical correlations capable of predicting Nu and f with an absolute variance of 8.7%, and 4.7%, respectively, are developed. Employing these correlations, exergetic performance analysis is carried out. Maximum effectiveness parameter (?) of 2.01 is obtained for ? = 45° at Re = 7500. The exergy analysis reveals that the entropy generated is lower for the ribbed triangular duct compared to the smooth duct with maximum enhancement in exergetic efficiency (?ex) as 23% for ? = 45°. The study is extended for the rectangular duct to compare the performance with the ribbed triangular duct SAH (? = 45°). Results show that ribbed triangular duct SAH (? = 45°) is superior over various configurations of the ribbed rectangular duct SAH at higher mass flow rates. © 2020 Elsevier Ltd
  • Item
    Computational and experimental studies on the development of an energy-efficient drier using ribbed triangular duct solar air heater
    (Elsevier Ltd, 2020) Nidhul, K.; Kumar, S.; Yadav, A.; Anish, S.
    Triangular duct cross-section is introduced for solar air heater (SAH) of an indirect type of solar dryer (ITSD). Using computational study, the thermo-hydraulic performance of triangular duct SAH with inclined ribs for varying rib inclination (30° < ? < 75°) in the turbulent flow regime (5000 < Re < 17500) is studied. With the rib configuration providing maximum thermos-hydraulic performance, a ribbed rectangular duct SAH is designed, and the performance of the same is compared to the former for similar heat input. Results show that the ribbed (? = 45°) triangular duct has 17% higher effectiveness compared to the latter and 79% when compared to smooth SAH. Ribs in triangular duct solar air heater facilitate the increase in temperature even in the core of the duct, delivering the air at 6 K additional temperature relative to a rectangular ribbed duct for same heat input and flow Re. The superiority of the ribbed triangular SAH is further confirmed by studying the drying characteristics of Okra and two variants of banana, namely Nendran and Robusta for the maximum temperature obtained at the outlet of the respective SAH. Various thin layer drying models available in the literature were analyzed, and Modified page model represented the drying behaviour with R2 = 0.99. For ITSD, ribbed triangular duct SAH exhibits a maximum of 60.3% reduction in moisture ratio with a maximum increase of 97.9% increase in average values of diffusivity coefficient confirming that it is an energy-efficient design for an ITSD. © 2020 International Solar Energy Society
  • Item
    Thermo-hydraulic and exergetic performance of a cost-effective solar air heater: CFD and experimental study
    (Elsevier Ltd, 2022) Nidhul, K.; Yadav, A.K.; Anish, S.; Arunachala, U.C.
    An experimental and computational fluid dynamics (CFD) study is carried out to investigate the impact of secondary flow strengthening the thermo-hydraulic performance of discrete multiple inclined baffles in a flat plate solar air heater (SAH) with semi-cylindrical sidewalls. Initially, for a fixed relative baffle height (Rh = 0.1), the relative baffle pitch (Rp) for continuous baffles is varied in the range of 0.6–1 to obtain the optimum baffle pitch for 6000 p. A maximum thermo-hydraulic performance of 2.69 is obtained for the gap at the trailing apex. The proposed design has a higher collector efficiency, 55–70%, compared to the ribbed rectangular SAH design exhibiting 30–55%. With lower exergy losses, the present SAH design has higher exergetic efficiency (1.5%–2.2%)than ribbed rectangular SAH (0.9%–1.7%) for the range of Re studied. Further, at low Re, the present SAH design has a higher coefficient of performance, indicating that it is cost-effective than ribbed rectangular SAH designs. © 2021 Elsevier Ltd
  • Item
    Energy and exergy analysis of solar air heater with non-uniform porous medium under varying solar intensity and radiation effects: a 3-D CFD study
    (Taylor and Francis Ltd., 2025) Nidhul, K.; Joshi, A.; Yadav, A.K.; Anish, S.
    The effect of a thin porous layer on the performance of a solar air heater (SAH) is investigated for both uniform and non-uniform configurations. 3-D computational fluid dynamic (CFD) simulations of SAH are performed for turbulent flow, and the transient performance with porous medium configurations is studied. A discrete-ordinate (D-O) model is employed, and diurnal variations of solar heat flux and inlet air temperature variations are considered in this study. The porous medium above the absorber plate significantly enhances the SAH's thermo-hydraulic performance parameter (THPP). The proposed configuration reduces the irreversibility in heat transfer and the possible hot spots that could occur when ribs are employed as artificial roughness, thereby enhancing the Nusselt number (Nu). The highest increment in Nu is obtained as 7.5 times, leading to maximum enhancement in THPP by 60% for descending porous medium compared to uniform porous medium configuration. Further, from the exergy analysis, the descending porous medium reported higher collector efficiency (66-70%). Owing to higher exergy gain and lower exergy losses, the energetic efficiency of the descending porous configuration is higher than the uniform porous configuration. Both thermo-hydraulic and exergy performance increases due to conduction and radiation within the porous medium apart from convection. © 2025 The Author(s). Published by Informa UK Limited, trading as Taylor & Francis Group.