Journal Articles
Permanent URI for this collectionhttps://idr.nitk.ac.in/handle/123456789/19884
Browse
3 results
Search Results
Item Enhanced thermo-hydraulic performance in a V-ribbed triangular duct solar air heater: CFD and exergy analysis(Elsevier Ltd, 2020) Nidhul, K.; Kumar, S.; Yadav, A.; Anish, S.Computational fluid dynamics (CFD) and exergy analysis are conducted to investigate the impact of secondary flow produced by V-ribs on the overall performance of a triangular solar air heater (SAH) duct. For a fixed relative rib pitch (Rp = 10) and relative rib height (Rh = 0.05), the effect of rib inclination (?) is studied using CFD technique for varying Reynolds number (5000 ? Re ? 20000). Based on the CFD simulation results, empirical correlations capable of predicting Nu and f with an absolute variance of 8.7%, and 4.7%, respectively, are developed. Employing these correlations, exergetic performance analysis is carried out. Maximum effectiveness parameter (?) of 2.01 is obtained for ? = 45° at Re = 7500. The exergy analysis reveals that the entropy generated is lower for the ribbed triangular duct compared to the smooth duct with maximum enhancement in exergetic efficiency (?ex) as 23% for ? = 45°. The study is extended for the rectangular duct to compare the performance with the ribbed triangular duct SAH (? = 45°). Results show that ribbed triangular duct SAH (? = 45°) is superior over various configurations of the ribbed rectangular duct SAH at higher mass flow rates. © 2020 Elsevier LtdItem Efficient design of an artificially roughened solar air heater with semi-cylindrical side walls: CFD and exergy analysis(Elsevier Ltd, 2020) Nidhul, K.; Yadav, A.; Anish, S.; Arunachala, U.C.Solar air heater (SAH) with semi-cylindrical sidewalls and W-baffles is analyzed for energy and exergy efficiency in the turbulent flow regime. Computational fluid dynamics (CFD) analysis is carried out for a fixed baffle inclination (?) and varying the relative baffle height (Rh = e/D) and relative baffle pitch (Rp = P/D) in the range 0.046–0.115 and 0.46–1.15, respectively. For Reynolds number (5000 < Re < 17,500), the numerical methodology is substantiated using experimental and theoretical correlations obtained from the literature. Smaller vortices near the sharp corners are removed by rounding the sharp edges, allowing the flow of fluid from inside and horizontal walls of the duct towards the semi-cylindrical sidewalls. This increases the overall turbulent kinetic energy. A peak augmentation of 3.24 and 4.03 times is obtained for Nusselt number (Nu) and friction factor (f), respectively, in contrast to conventional SAH. With a maximum enhancement of 127% in the effectiveness parameter relative to smooth SAH, this novel SAH design is evidently energy efficient. Based on CFD results, new correlations are developed in terms of Rh and Rp, which predicts the values with an absolute deviation of 4% and 7.4%, respectively. With lower exergy destruction, maximum enhancement in thermal and exergetic efficiency is obtained as 40.7% and 95.4%, respectively, for the proposed SAH relative to conventional SAH. Upon comparison with ribbed rectangular duct SAH configurations, the present design with semi-cylindrical side walls outperforms at all flow Re. © 2020 International Solar Energy SocietyItem Thermo-hydraulic and exergetic performance of a cost-effective solar air heater: CFD and experimental study(Elsevier Ltd, 2022) Nidhul, K.; Yadav, A.K.; Anish, S.; Arunachala, U.C.An experimental and computational fluid dynamics (CFD) study is carried out to investigate the impact of secondary flow strengthening the thermo-hydraulic performance of discrete multiple inclined baffles in a flat plate solar air heater (SAH) with semi-cylindrical sidewalls. Initially, for a fixed relative baffle height (Rh = 0.1), the relative baffle pitch (Rp) for continuous baffles is varied in the range of 0.6–1 to obtain the optimum baffle pitch for 6000 p. A maximum thermo-hydraulic performance of 2.69 is obtained for the gap at the trailing apex. The proposed design has a higher collector efficiency, 55–70%, compared to the ribbed rectangular SAH design exhibiting 30–55%. With lower exergy losses, the present SAH design has higher exergetic efficiency (1.5%–2.2%)than ribbed rectangular SAH (0.9%–1.7%) for the range of Re studied. Further, at low Re, the present SAH design has a higher coefficient of performance, indicating that it is cost-effective than ribbed rectangular SAH designs. © 2021 Elsevier Ltd
