Repository logo
Communities & Collections
All of DSpace
  • English
  • العربية
  • বাংলা
  • Català
  • Čeština
  • Deutsch
  • Ελληνικά
  • Español
  • Suomi
  • Français
  • Gàidhlig
  • हिंदी
  • Magyar
  • Italiano
  • Қазақ
  • Latviešu
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Srpski (lat)
  • Српски
  • Svenska
  • Türkçe
  • Yкраї́нська
  • Tiếng Việt
Log In
Have you forgotten your password?
  1. Home
  2. Browse by Author

Browsing by Author "Krishna Kumar, P."

Filter results by typing the first few letters
Now showing 1 - 3 of 3
  • Results Per Page
  • Sort Options
  • No Thumbnail Available
    Item
    Accurate lumen diameter measurement in curved vessels in carotid ultrasound: an iterative scale-space and spatial transformation approach
    (Springer Verlag service@springer.de, 2017) Krishna Kumar, P.; Araki, T.; Rajan, J.; Saba, L.; Lavra, F.; Ikeda, N.; Sharma, A.M.; Shafique, S.; Nicolaïdes, A.; Laird, J.R.; Gupta, A.; Suri, J.S.
    Monitoring of cerebrovascular diseases via carotid ultrasound has started to become a routine. The measurement of image-based lumen diameter (LD) or inter-adventitial diameter (IAD) is a promising approach for quantification of the degree of stenosis. The manual measurements of LD/IAD are not reliable, subjective and slow. The curvature associated with the vessels along with non-uniformity in the plaque growth poses further challenges. This study uses a novel and generalized approach for automated LD and IAD measurement based on a combination of spatial transformation and scale-space. In this iterative procedure, the scale-space is first used to get the lumen axis which is then used with spatial image transformation paradigm to get a transformed image. The scale-space is then reapplied to retrieve the lumen region and boundary in the transformed framework. Then, inverse transformation is applied to display the results in original image framework. Two hundred and two patients’ left and right common carotid artery (404 carotid images) B-mode ultrasound images were retrospectively analyzed. The validation of our algorithm has done against the two manual expert tracings. The coefficient of correlation between the two manual tracings for LD was 0.98 (p < 0.0001) and 0.99 (p < 0.0001), respectively. The precision of merit between the manual expert tracings and the automated system was 97.7 and 98.7%, respectively. The experimental analysis demonstrated superior performance of the proposed method over conventional approaches. Several statistical tests demonstrated the stability and reliability of the automated system. © 2016, International Federation for Medical and Biological Engineering.
  • No Thumbnail Available
    Item
    Carotid inter-adventitial diameter is more strongly related to plaque score than lumen diameter: An automated tool for stroke analysis
    (John Wiley and Sons Inc. P.O.Box 18667 Newark NJ 07191-8667, 2016) Saba, L.; Araki, T.; Krishna Kumar, P.; Rajan, J.; Lavra, F.; Ikeda, N.; Sharma, A.M.; Shafique, S.; Nicolaïdes, A.; Laird, J.R.; Gupta, A.; Suri, J.S.
    Purpose: To compare the strength of correlation between automatically measured carotid lumen diameter (LD) and interadventitial diameter (IAD) with plaque score (PS). Methods: Retrospective study on a database of 404 common carotid artery B-mode sonographic images from 202 diabetic patients. LD and IAD were computed automatically using an advanced computerized edge detection method and compared with two distinct manual measurements. PS was computed by adding the maximal thickness in millimeters of plaques in segments taken from the internal carotid artery, bulb, and common carotid artery on both sides. Results: The coefficient of correlation was 0.19 (p < 0.007) between LD and PS, and 0.25 (p < 0.0006) between IAD and PS. After excluding 10 outliers, coefficient of correlation was 0.25 (p < 0.0001) between LD and PS, and 0.38 (p < 0.0001) between IAD and PS. The precision of merit of automated versus the two manual measurements was 96.6% and 97.2% for LD, and 97.7% and 98.1%, for IAD, respectively. Conclusions: Our automated measurement system gave satisfying results in comparison with manual measurements. Carotid IAD was more strongly correlated to PS than carotid LD in this population sample of Japanese diabetic patients. © 2016 Wiley Periodicals, Inc.
  • No Thumbnail Available
    Item
    Fourth order PDE based ultrasound despeckling using ENI classification
    (Institute of Electrical and Electronics Engineers Inc., 2016) Soorajkumar, R.; Krishna Kumar, P.; Girish, D.; Rajan, J.
    Medical ultrasound images are generally corrupted with a type of signal dependent noise called speckle. The major reason for the speckle in ultrasound images is the constructive or destructive interference of ultrasound waves. The granular pattern of the speckle noise degrades the image and hinders the information present in it. In this work, we developed an improved speckle denoising method using a fourth order partial differential equation (PDE) model by integrating Edge Noise Interior method in it. Edge Noise Interior (ENI) method preserves the edges and counts the number of homogeneous pixels in the neighbourhood to classify the edges. Furthermore, a maximum likelihood technique is used to estimate and remove the bias in the denoised images. The proposed method is compared against other existing methods and validated for both simulated as well as real ultrasound images. The proposed method outperforms other state-of-the-art methods in terms of qualitative and quantitative analysis. © 2016 IEEE.

Maintained by Central Library NITK | DSpace software copyright © 2002-2026 LYRASIS

  • Privacy policy
  • End User Agreement
  • Send Feedback
Repository logo COAR Notify