Repository logo
Communities & Collections
All of DSpace
  • English
  • العربية
  • বাংলা
  • Català
  • Čeština
  • Deutsch
  • Ελληνικά
  • Español
  • Suomi
  • Français
  • Gàidhlig
  • हिंदी
  • Magyar
  • Italiano
  • Қазақ
  • Latviešu
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Srpski (lat)
  • Српски
  • Svenska
  • Türkçe
  • Yкраї́нська
  • Tiếng Việt
Log In
Have you forgotten your password?
  1. Home
  2. Browse by Author

Browsing by Author "Bukkitgar, S.D."

Filter results by typing the first few letters
Now showing 1 - 2 of 2
  • Results Per Page
  • Sort Options
  • No Thumbnail Available
    Item
    Electro-oxidation of nimesulide at 5% barium-doped zinc oxide nanoparticle modified glassy carbon electrode
    (2016) Bukkitgar, S.D.; Shetti, N.P.; Kulkarni, R.M.; Doddamani, M.
    Development of methods for the detection of an analyte at low concentration with less time for analysis has become a prior point of interest to every analyst. In reflection of this fact, an effort has been made to synthesize 5% barium doped zinc oxide nanoparticles and was characterized by using XRD, EDX, SEM, and TEM. Further, 5% barium doped zinc oxide nanoparticle modified glassy carbon electrode was used for investigating the electro-chemical behavior of nimesulide. Voltammograms obtained in a range of 3.0-11.2 (I = 0.2 M) pH had a maximum peak current at pH 7.0. Various physio-chemical parameters such as, process on the surface of the electrode, which was found to be diffusion controlled, heterogeneous rate constant, number of electrons transferred and charge transfer coefficient were estimated. Further, a method for nimesulide determination in a linear range of 1.0 10- 5 to 1.0 10- 7 M with LOD 1.794 nM was proposed. This technique was later used for analytical application. 2015 Elsevier Ltd. All rights reserved.
  • No Thumbnail Available
    Item
    Electro-oxidation of nimesulide at 5% barium-doped zinc oxide nanoparticle modified glassy carbon electrode
    (Elsevier B.V., 2016) Bukkitgar, S.D.; Shetti, N.P.; Kulkarni, R.M.; Doddamani, M.R.
    Development of methods for the detection of an analyte at low concentration with less time for analysis has become a prior point of interest to every analyst. In reflection of this fact, an effort has been made to synthesize 5% barium doped zinc oxide nanoparticles and was characterized by using XRD, EDX, SEM, and TEM. Further, 5% barium doped zinc oxide nanoparticle modified glassy carbon electrode was used for investigating the electro-chemical behavior of nimesulide. Voltammograms obtained in a range of 3.0-11.2 (I = 0.2 M) pH had a maximum peak current at pH 7.0. Various physio-chemical parameters such as, process on the surface of the electrode, which was found to be diffusion controlled, heterogeneous rate constant, number of electrons transferred and charge transfer coefficient were estimated. Further, a method for nimesulide determination in a linear range of 1.0 × 10- 5 to 1.0 × 10- 7 M with LOD 1.794 nM was proposed. This technique was later used for analytical application. © 2015 Elsevier Ltd. All rights reserved.

Maintained by Central Library NITK | DSpace software copyright © 2002-2026 LYRASIS

  • Privacy policy
  • End User Agreement
  • Send Feedback
Repository logo COAR Notify